Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Arizona State University
Assessment Year 1994
Principal Product Printed Circuit boards
NAICS n/a
SIC 3672 - Printed Circuit Boards
Sales $50,000,000-$100,000,000
# of Employees 850
Plant Area (Sq.Ft.) 162,075
Annual Production 200,000 Pieces
Production Hrs. Annual 8,760
Location (State) AZ
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $1,846,926 28,640,973 kWh $0.06
Natural Gas $24,686 4,546 MMBtu $5.43
TOTAL ENERGY COSTS $1,871,612
RECOMMENDED SAVINGS* $158,846 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $143,343
#|Description Savings
Cost
Status Electricity Usage Electricity Usage
$ kWh
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$60,465
Cost:
$81,258
$60,465 937,573 $60,465
937,573
kWh
02: 2.7135 INSTALL OCCUPANCY SENSORS Savings:
$4,022
Cost:
$2,265
$4,022 62,427 $4,022
62,427
kWh
03: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS Savings:
$33,572
Cost:
$18,827
$33,572 520,516 $33,572
520,516
kWh
04: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS Savings:
$981
Cost:
-
$981 15,240 $981
15,240
kWh
05: 2.4314 USE SYNTHETIC LUBRICANT Savings:
$6,773
Cost:
$8,970
$6,773 68,288 $6,773
68,288
kWh
06: 2.2511 INSULATE BARE EQUIPMENT Savings:
$7,749
Cost:
$3,050
$7,749 120,164 $7,749
120,164
kWh
07: 2.7232 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL Savings:
$45,284
Cost:
$83,400
$45,284 702,227 $45,284
702,227
kWh
TOTAL RECOMMENDED Savings:
$158,846
Cost:
$197,770
$158,846 2,426,435 $158,846
2,426,435
kWh
TOTAL IMPLEMENTED Savings:
$143,343
Cost:
$185,750
$143,343 2,222,743 $143,343
2,222,743
kWh
Savings
Cost
$ kWh