Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Arizona State University
Assessment Year 1995
Principal Product Chocolate Candy
NAICS n/a
SIC 2064 - Candy & Other Confectionery Products
Sales $1,000,000-$5,000,000
# of Employees 35
Plant Area (Sq.Ft.) 35,000
Annual Production 670,000 Pounds
Production Hrs. Annual 2,340
Location (State) AZ
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $46,613 459,555 kWh $0.10
Natural Gas $5,178 746 MMBtu $6.94
TOTAL ENERGY COSTS $51,791
RECOMMENDED SAVINGS* $8,838 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $1,038
#|Description Savings
Cost
Status Electricity Usage Natural Gas Electricity Usage Natural Gas
$ kWh $ MMBtu
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$797
Cost:
$690
$797 8,206 - - $797
8,206
kWh
-
-
MMBtu
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$2,748
Cost:
$2,943
$2,748 33,118 - - $2,748
33,118
kWh
-
-
MMBtu
03: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS Savings:
$734
Cost:
$1,386
$734 5,569 - - $734
5,569
kWh
-
-
MMBtu
04: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS Savings:
$159
Cost:
-
$159 1,465 - - $159
1,465
kWh
-
-
MMBtu
05: 2.2622 REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL Savings:
$4,099
Cost:
$13,500
$4,099 36,342 - - $4,099
36,342
kWh
-
-
MMBtu
06: 2.2414 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT Savings:
$156
Cost:
$500
- - $156 22 -
-
kWh
$156
22
MMBtu
07: 2.2511 INSULATE BARE EQUIPMENT Savings:
$145
Cost:
$173
$39 586 $106 15 $39
586
kWh
$106
15
MMBtu
TOTAL RECOMMENDED Savings:
$8,838
Cost:
$19,192
$8,576 85,286 $262 37 $8,576
85,286
kWh
$262
37
MMBtu
TOTAL IMPLEMENTED Savings:
$1,038
Cost:
$1,559
$932 7,620 $106 15 $932
7,620
kWh
$106
15
MMBtu
Savings
Cost
$ kWh $ MMBtu
Electricity Usage Natural Gas Electricity Usage Natural Gas