Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Arizona State University |
---|---|
Assessment Year | 1998 |
Principal Product | Refrigerators and Freezers |
NAICS | n/a |
SIC | 3632 - Household Refrigerators And Freezers |
Sales | $10,000,000-$50,000,000 |
# of Employees | 156 |
Plant Area (Sq.Ft.) | 120,000 |
Annual Production | 19,000 Pieces |
Production Hrs. Annual | 4,125 |
Location (State) | AZ |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $211,441 | 2,787,808 | kWh | $0.08 |
Electricity Demand | $20,362 | 11,492 | kW-months/year | $1.77 |
Electricity Fees | $15,917 | - | $ | - |
Natural Gas | $35,084 | 7,018 | MMBtu | $5.00 |
TOTAL ENERGY COSTS | $294,027 | |||
RECOMMENDED SAVINGS* | $1,620,414 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $7,275 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Administrative Changes | Primary Raw Material | Increase in Production | Electricity Usage | Electricity Demand | Administrative Changes | Primary Raw Material | Increase in Production | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | $ | % | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $681 Cost: $3,333 |
$403 | 8,206 | $278 | 33 | - | - | - | - | - | - |
$403 8,206 kWh |
$278 33 kW-months/year |
- - $ |
- - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $457 Cost: $1,200 |
$174 | 5,862 | $283 | 21 | - | - | - | - | - | - |
$174 5,862 kWh |
$283 21 kW-months/year |
- - $ |
- - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $333 Cost: $284 |
$136 | 4,103 | $197 | 16 | - | - | - | - | - | - |
$136 4,103 kWh |
$197 16 kW-months/year |
- - $ |
- - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7133 USE SEPARATE SWITCHES ON PERIMETER LIGHTING WHICH MAY BE TURNED OFF WHEN NATURAL LIGHT IS AVAILABLE |
Savings: $417 Cost: $320 |
$417 | 8,499 | - | - | - | - | - | - | - | - |
$417 8,499 kWh |
- - kW-months/year |
- - $ |
- - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $249 Cost: $406 |
$210 | 4,396 | $39 | 5 | - | - | - | - | - | - |
$210 4,396 kWh |
$39 5 kW-months/year |
- - $ |
- - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $2,335 Cost: $4,124 |
$1,558 | 31,946 | $777 | 93 | - | - | - | - | - | - |
$1,558 31,946 kWh |
$777 93 kW-months/year |
- - $ |
- - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $2,347 Cost: $9,180 |
$2,347 | 48,359 | - | - | - | - | - | - | - | - |
$2,347 48,359 kWh |
- - kW-months/year |
- - $ |
- - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.7232 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL |
Savings: $1,225 Cost: $3,150 |
$992 | 20,516 | $233 | 42 | - | - | - | - | - | - |
$992 20,516 kWh |
$233 42 kW-months/year |
- - $ |
- - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 3.5316 CONTRACT A WOOD PALLET RECYCLING COMPANY |
Savings: $1,775 Cost: $60 |
- | - | - | - | $1,775 | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$1,775 - $ |
- - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 3.6192 USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL |
Savings: $941 Cost: $60 |
- | - | - | - | $941 | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$941 - $ |
- - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
11: 4.621 USE FIXTURES TO REDUCE MACHINE CHANGEOUT TIMES |
Savings: $1,609,654 Cost: $4,960 |
$1,934 | 39,859 | $965 | 116 | - | - | $(-3,245) | - | $1,610,000 | - |
$1,934 39,859 kWh |
$965 116 kW-months/year |
- - $ |
$(-3,245) - $ |
$1,610,000 - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $1,620,414 Cost: $27,077 |
$8,171 | 171,746 | $2,772 | 326 | $2,716 | - | $(-3,245) | - | $1,610,000 | - | $8,171 171,746 kWh |
$2,772 326 kW-months/year |
$2,716 - $ |
$(-3,245) - $ |
$1,610,000 - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $7,275 Cost: $8,404 |
$3,313 | 69,460 | $1,246 | 156 | $2,716 | - | - | - | - | - | $3,313 69,460 kWh |
$1,246 156 kW-months/year |
$2,716 - $ |
- - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | $ | % | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Administrative Changes | Primary Raw Material | Increase in Production | Electricity Usage | Electricity Demand | Administrative Changes | Primary Raw Material | Increase in Production |