Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Arizona State University |
---|---|
Assessment Year | 2000 |
Principal Product | Electronics |
NAICS | n/a |
SIC | 3629 - Electrical Industrial Apparatus, Nec |
Sales | $10,000,000-$50,000,000 |
# of Employees | 125 |
Plant Area (Sq.Ft.) | 50,000 |
Annual Production | 180,000 Pieces |
Production Hrs. Annual | 4,000 |
Location (State) | AZ |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $87,713 | 1,383,646 | kWh | $0.06 |
Electricity Demand | $31,876 | 4,126 | kW-months/year | $7.73 |
Electricity Fees | $6,164 | - | $ | - |
Natural Gas | $13,770 | 2,055 | MMBtu | $6.70 |
TOTAL ENERGY COSTS | $145,524 | |||
RECOMMENDED SAVINGS* | $58,595 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | - |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Water Disposal | Personnel Changes | Administrative Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Water Disposal | Personnel Changes | Administrative Changes | Ancillary Material Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | Tgal | $ | $ | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $367 Cost: $380 |
$279 | 4,396 | $88 | 13 | - | - | - | - | - | - | - | - |
$279 4,396 kWh |
$88 13 kW-months/year |
- - Tgal |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $1,665 Cost: $2,256 |
$1,267 | 19,343 | $398 | 67 | - | - | - | - | - | - | - | - |
$1,267 19,343 kWh |
$398 67 kW-months/year |
- - Tgal |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $477 Cost: $544 |
$286 | 4,396 | $35 | 5 | - | - | $78 | - | - | - | $78 | - |
$286 4,396 kWh |
$35 5 kW-months/year |
- - Tgal |
$78 - $ |
- - $ |
$78 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.2511 INSULATE BARE EQUIPMENT |
Savings: $981 Cost: $272 |
$981 | 14,947 | - | - | - | - | - | - | - | - | - | - |
$981 14,947 kWh |
- - kW-months/year |
- - Tgal |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 3.4156 USE FLOW CONTROL VALVES ON EQUIPMENT TO OPTIMIZE WATER USE |
Savings: $2,017 Cost: $120 |
- | - | - | - | $2,017 | 725,600 | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$2,017 725,600 Tgal |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 3.6192 USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL |
Savings: $588 Cost: $60 |
- | - | - | - | - | - | - | - | $588 | - | - | - |
- - kWh |
- - kW-months/year |
- - Tgal |
- - $ |
$588 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 4.452 ELIMINATE SHIFT |
Savings: $52,500 Cost: $16,000 |
- | - | - | - | - | - | $52,500 | - | - | - | - | - |
- - kWh |
- - kW-months/year |
- - Tgal |
$52,500 - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $58,595 Cost: $19,632 |
$2,813 | 43,082 | $521 | 85 | $2,017 | 725,600 | $52,578 | - | $588 | - | $78 | - | $2,813 43,082 kWh |
$521 85 kW-months/year |
$2,017 725,600 Tgal |
$52,578 - $ |
$588 - $ |
$78 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: - Cost: - |
- | - | - | - | - | - | - | - | - | - | - | - | - - kWh |
- - kW-months/year |
- - Tgal |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | Tgal | $ | $ | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Water Disposal | Personnel Changes | Administrative Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Water Disposal | Personnel Changes | Administrative Changes | Ancillary Material Cost |