Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Arizona State University |
---|---|
Assessment Year | 2004 |
Principal Product | Citrus Juices |
NAICS | 311421 - Fruit and Vegetable Canning |
SIC | 2033 - Canned Fruits And Vegetables |
Sales | $10,000,000-$50,000,000 |
# of Employees | 65 |
Plant Area (Sq.Ft.) | 40,000 |
Annual Production | 2,000 Thousand Gallons |
Production Hrs. Annual | 7,344 |
Location (State) | AZ |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $103,629 | 1,790,400 | kWh | $0.06 |
Electricity Demand | $11,142 | 4,385 | kW-months/year | $2.54 |
Electricity Fees | $8,314 | - | $ | - |
Natural Gas | $24,396 | 4,214 | MMBtu | $5.79 |
TOTAL ENERGY COSTS | $199,976 | |||
RECOMMENDED SAVINGS* | $57,349 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $14,811 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Ancillary Material Cost | Electricity Usage | Electricity Demand | Natural Gas | Ancillary Material Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.2441 PREHEAT BOILER MAKEUP WATER WITH WASTE PROCESS HEAT |
Savings: $14,811 Cost: $5,240 |
- | - | - | - | $14,811 | 2,664 | - | - |
- - kWh |
- - kW-months/year |
$14,811 2,664 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.3415 USE A FOSSIL FUEL ENGINE TO COGENERATE ELECTRICITY OR MOTIVE POWER; AND UTILIZE HEAT |
Savings: $36,297 Cost: $90,000 |
$103,629 | 1,790,000 | $11,142 | 4,385 | $(-78,474) | (-14,114) | - | - |
$103,629 1,790,000 kWh |
$11,142 4,385 kW-months/year |
$(-78,474) (-14,114) MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.1221 REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES |
Savings: $3,275 Cost: $4,395 |
- | - | - | - | $3,275 | 589 | - | - |
- - kWh |
- - kW-months/year |
$3,275 589 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $1,352 Cost: $9,037 |
$577 | 14,582 | $352 | 43 | - | - | $423 | - |
$577 14,582 kWh |
$352 43 kW-months/year |
- - MMBtu |
$423 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7145 INSTALL SKYLIGHTS |
Savings: $708 Cost: $3,395 |
$708 | 17,885 | - | - | - | - | - | - |
$708 17,885 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7232 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL |
Savings: $567 Cost: $1,500 |
$299 | 7,552 | $268 | 33 | - | - | - | - |
$299 7,552 kWh |
$268 33 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $339 Cost: $460 |
$279 | 7,045 | $60 | 7 | - | - | - | - |
$279 7,045 kWh |
$60 7 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $57,349 Cost: $114,027 |
$105,492 | 1,837,064 | $11,822 | 4,468 | $(-60,388) | (-10,861) | $423 | - | $105,492 1,837,064 kWh |
$11,822 4,468 kW-months/year |
$(-60,388) (-10,861) MMBtu |
$423 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $14,811 Cost: $5,240 |
- | - | - | - | $14,811 | 2,664 | - | - | - - kWh |
- - kW-months/year |
$14,811 2,664 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Ancillary Material Cost | Electricity Usage | Electricity Demand | Natural Gas | Ancillary Material Cost |