Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Arizona State University |
---|---|
Assessment Year | 2004 |
Principal Product | Raw Milk |
NAICS | 112120 - Dairy Cattle and Milk Production |
SIC | 241 - Logging |
Sales | $10,000,000-$50,000,000 |
# of Employees | 50 |
Plant Area (Sq.Ft.) | 1,000,000 |
Annual Production | 84,862,500 Pounds |
Production Hrs. Annual | 8,760 |
Location (State) | AZ |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $176,980 | 4,657,360 | kWh | $0.04 |
Electricity Demand | $125,837 | 14,139 | kW-months/year | $8.90 |
Electricity Fees | $3,564 | - | $ | - |
TOTAL ENERGY COSTS | $306,381 | |||
RECOMMENDED SAVINGS* | $209,120 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $35,874 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Fuel Oil #2 | Electricity Usage | Electricity Demand | Fuel Oil #2 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $996 Cost: $691 |
$609 | 15,120 | $387 | 50 | - | - |
$609 15,120 kWh |
$387 50 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $198 Cost: $120 |
$144 | 3,572 | $54 | 6 | - | - |
$144 3,572 kWh |
$54 6 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.9112 USE SOLAR HEAT TO HEAT WATER |
Savings: $868 Cost: $1,530 |
- | - | - | - | $868 | 120 |
- - kWh |
- - kW-months/year |
$868 120 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.1331 BURN A LESS EXPENSIVE GRADE OF FUEL |
Savings: $170,924 Cost: $52,200 |
$128,340 | 3,184,617 | $41,269 | 4,362 | $1,315 | 121 |
$128,340 3,184,617 kWh |
$41,269 4,362 kW-months/year |
$1,315 121 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $13,394 Cost: $17,193 |
$10,135 | 251,486 | $3,259 | 346 | - | - |
$10,135 251,486 kWh |
$3,259 346 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7232 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL |
Savings: $260 Cost: $(-220) |
$165 | 5,124 | $95 | 16 | - | - |
$165 5,124 kWh |
$95 16 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $22,480 Cost: $10,717 |
$19,552 | 423,213 | $2,928 | 659 | - | - |
$19,552 423,213 kWh |
$2,928 659 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $209,120 Cost: $82,231 |
$158,945 | 3,883,132 | $47,992 | 5,439 | $2,183 | 241 | $158,945 3,883,132 kWh |
$47,992 5,439 kW-months/year |
$2,183 241 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $35,874 Cost: $27,910 |
$29,687 | 674,699 | $6,187 | 1,005 | - | - | $29,687 674,699 kWh |
$6,187 1,005 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Fuel Oil #2 | Electricity Usage | Electricity Demand | Fuel Oil #2 |