Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Arizona State University
Assessment Year 2004
Principal Product Packaged Salad
NAICS 311991 - Perishable Prepared Food Manufacturing
SIC 2099 - Food Preparations, Nec
Sales $100,000,000-$500,000,000
# of Employees 250
Plant Area (Sq.Ft.) 225,000
Annual Production 13,000,000 Pieces
Production Hrs. Annual 6,489
Location (State) AZ
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $646,120 11,450,100 kWh $0.06
Electricity Demand $41,538 25,550 kW-months/year $1.63
Electricity Fees $62,650 - $ -
TOTAL ENERGY COSTS $750,308
RECOMMENDED SAVINGS* $3,315,434 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $43,207
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Personnel Changes Electricity Usage Electricity Demand Personnel Changes
$ kWh $ kW-months/year $ $
01: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$34,302
Cost:
$480
$29,114 622,087 $5,188 1,150 - - $29,114
622,087
kWh
$5,188
1,150
kW-months/year
-
-
$
02: 4.441 INSTALL AUTOMATIC PACKING EQUIPMENT Savings:
$3,270,456
Cost:
$3,624,320
- - - - $3,270,456 - -
-
kWh
-
-
kW-months/year
$3,270,456
-
$
03: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE Savings:
$1,133
Cost:
$506
$1,133 24,204 - - - - $1,133
24,204
kWh
-
-
kW-months/year
-
-
$
04: 2.7232 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL Savings:
$2,081
Cost:
$499
$1,766 37,728 $315 70 - - $1,766
37,728
kWh
$315
70
kW-months/year
-
-
$
05: 2.2515 USE OPTIMUM THICKNESS INSULATION Savings:
$638
Cost:
$360
$521 11,137 $117 26 - - $521
11,137
kWh
$117
26
kW-months/year
-
-
$
06: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$2,918
Cost:
$12,008
$2,477 52,931 $441 98 - - $2,477
52,931
kWh
$441
98
kW-months/year
-
-
$
07: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS Savings:
$3,906
Cost:
$6,178
$3,282 70,136 $624 138 - - $3,282
70,136
kWh
$624
138
kW-months/year
-
-
$
TOTAL RECOMMENDED Savings:
$3,315,434
Cost:
$3,644,351
$38,293 818,223 $6,685 1,482 $3,270,456 - $38,293
818,223
kWh
$6,685
1,482
kW-months/year
$3,270,456
-
$
TOTAL IMPLEMENTED Savings:
$43,207
Cost:
$19,165
$36,639 782,882 $6,568 1,456 - - $36,639
782,882
kWh
$6,568
1,456
kW-months/year
-
-
$
Savings
Cost
$ kWh $ kW-months/year $ $
Electricity Usage Electricity Demand Personnel Changes Electricity Usage Electricity Demand Personnel Changes