IAC Center Arizona State University
Assessment Year 2019
Principal Product Commercial paper rolls
NAICS 322121 - Paper (except Newsprint) Mills
SIC 2621 - Paper Mills
Sales $35,000,000
# of Employees 132
Plant Area (Sq.Ft.) 350,000
Annual Production 3,300,000 not found
Production Hrs. Annual 6,069
Location (State) AZ
Source Yearly Cost Usage
Electricity Usage $200,314 3,230,883
Electricity Demand $148,996 10,383
TOTAL ENERGY COSTS $349,310
RECOMMENDED SAVINGS* $76,753 *Non-energy impacts
included in savings.
IMPLEMENTED SAVINGS* -
#|Description Status Electricity Usage Electricity Demand Electricity Usage Electricity Demand
$ kWh $ kW/month
01: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS Savings:
$47,588
Cost:
$48,177
$33,520 540,691 $14,068 981 $33,520
540,691
kWh
$14,068
981
kW/month
02: 2.7232 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL Savings:
$12,397
Cost:
$53,000
$6,485 104,580 $5,912 412 $6,485
104,580
kWh
$5,912
412
kW/month
03: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$10,754
Cost:
$16,690
$7,378 119,000 $3,376 235 $7,378
119,000
kWh
$3,376
235
kW/month
04: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED Savings:
$6,014
Cost:
$200
$4,126 66,555 $1,888 132 $4,126
66,555
kWh
$1,888
132
kW/month
TOTAL RECOMMENDED Savings:
$76,753
Cost:
$118,067
$51,509 830,826 $25,244 1,760 $51,509
830,826
kWh
$25,244
1,760
kW/month
TOTAL IMPLEMENTED Savings:
-
Cost:
-
- - - - -
-
kWh
-
-
kW/month
$ kWh $ kW/month
Electricity Usage Electricity Demand Electricity Usage Electricity Demand
Back to Top