Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Arizona State University |
---|---|
Assessment Year | 2021 |
Principal Product | Potable Water |
NAICS | 221310 - Water Supply and Irrigation Systems |
SIC | 4941 - Water Supply |
Sales | <$500,000 |
# of Employees | 18 |
Plant Area (Sq.Ft.) | 61,006 |
Annual Production | 13,067,000 Thousand Gallons |
Production Hrs. Annual | 8,760 |
Location (State) | AZ |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $661,588 | 12,159,279 | kWh | $0.05 |
Electricity Demand | $221,627 | 26,349 | kW-months/year | $8.41 |
Electricity Fees | $83,879 | - | $ | - |
TOTAL ENERGY COSTS | $967,094 | |||
RECOMMENDED SAVINGS* | $93,853 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $16,258 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Coal | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | Electricity Fees | Coal | One-time Revenue or Avoided Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.8112 COMBINE UTILITY METERS |
Savings: $73,584 Cost: $1,313 |
- | - | - | - | $17,170 | - | $56,414 | - | - | - |
- - kWh |
- - kW-months/year |
$17,170 - $ |
$56,414 - MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.3131 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS |
Savings: $8,984 Cost: $2,000 |
$3,159 | - | $5,825 | - | - | - | - | - | - | - |
$3,159 - kWh |
$5,825 - kW-months/year |
- - $ |
- - MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7232 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL |
Savings: $4,011 Cost: $18,815 |
$2,788 | 51,241 | $1,223 | 146 | - | - | - | - | - | - |
$2,788 51,241 kWh |
$1,223 146 kW-months/year |
- - $ |
- - MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $3,467 Cost: $4,029 |
$2,465 | 45,305 | $522 | 62 | - | - | - | - | $480 | - |
$2,465 45,305 kWh |
$522 62 kW-months/year |
- - $ |
- - MMBtu |
$480 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $2,778 Cost: $3,974 |
$2,778 | 48,597 | - | - | - | - | - | - | - | - |
$2,778 48,597 kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7272 INSTALL HEAT PIPES / RAISE COOLING SETPOINT |
Savings: $1,029 Cost: $245 |
$697 | 12,890 | $332 | 39 | - | - | - | - | - | - |
$697 12,890 kWh |
$332 39 kW-months/year |
- - $ |
- - MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $93,853 Cost: $30,376 |
$11,887 | 158,033 | $7,902 | 247 | $17,170 | - | $56,414 | - | $480 | - | $11,887 158,033 kWh |
$7,902 247 kW-months/year |
$17,170 - $ |
$56,414 - MMBtu |
$480 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $16,258 Cost: $10,248 |
$9,099 | 106,792 | $6,679 | 101 | - | - | - | - | $480 | - | $9,099 106,792 kWh |
$6,679 101 kW-months/year |
- - $ |
- - MMBtu |
$480 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||