Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Arizona State University |
---|---|
Assessment Year | 2022 |
Principal Product | Refrigerated warehousing and storage |
NAICS | 493120 - Refrigerated Warehousing and Storage |
SIC | 4222 - Refrigerated Warehousing And Storage |
Sales | $1,000,000-$5,000,000 |
# of Employees | 8 |
Plant Area (Sq.Ft.) | 5,500 |
Annual Production | 1 Units |
Production Hrs. Annual | 2,762 |
Location (State) | AZ |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $8,933 | 109,305 | kWh | $0.08 |
Electricity Demand | $2,252 | 273 | kW-months/year | $8.25 |
Electricity Fees | $3,419 | - | $ | - |
TOTAL ENERGY COSTS | $14,604 | |||
RECOMMENDED SAVINGS* | $3,948 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $3,948 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Ancillary Material Cost | By-product Production | Electricity Usage | Electricity Demand | Ancillary Material Cost | By-product Production | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 4.621 USE FIXTURES TO REDUCE MACHINE CHANGEOUT TIMES |
Savings: $1,896 Cost: $1,099 |
$(-2,485) | (-30,420) | $(-619) | (-75) | - | - | $5,000 | - |
$(-2,485) (-30,420) kWh |
$(-619) (-75) kW-months/year |
- - $ |
$5,000 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $1,264 Cost: $2,187 |
$896 | 10,967 | $368 | 45 | - | - | - | - |
$896 10,967 kWh |
$368 45 kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7444 CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS |
Savings: $638 Cost: $115 |
$452 | 5,529 | $186 | 23 | - | - | - | - |
$452 5,529 kWh |
$186 23 kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $150 Cost: $317 |
$118 | 1,446 | $21 | 3 | $11 | - | - | - |
$118 1,446 kWh |
$21 3 kW-months/year |
$11 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $3,948 Cost: $3,718 |
$(-1,019) | (-12,478) | $(-44) | (-5) | $11 | - | $5,000 | - | $(-1,019) (-12,478) kWh |
$(-44) (-5) kW-months/year |
$11 - $ |
$5,000 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $3,948 Cost: $3,718 |
$(-1,019) | (-12,478) | $(-44) | (-5) | $11 | - | $5,000 | - | $(-1,019) (-12,478) kWh |
$(-44) (-5) kW-months/year |
$11 - $ |
$5,000 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Ancillary Material Cost | By-product Production | Electricity Usage | Electricity Demand | Ancillary Material Cost | By-product Production |