Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Bradley University |
---|---|
Assessment Year | 1998 |
Principal Product | Vinyl Windows and Sliding Glass Doors |
NAICS | n/a |
SIC | 3089 - Plastics Products, Nec |
Sales | $5,000,000-$10,000,000 |
# of Employees | 78 |
Plant Area (Sq.Ft.) | 78,000 |
Annual Production | 60,000 Pieces |
Production Hrs. Annual | 5,200 |
Location (State) | IL |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $25,817 | 589,977 | kWh | $0.04 |
Electricity Demand | $22,702 | 1,896 | kW-months/year | $11.97 |
Electricity Fees | $509 | - | $ | - |
Natural Gas | $10,260 | 1,855 | MMBtu | $5.53 |
TOTAL ENERGY COSTS | $73,003 | |||
RECOMMENDED SAVINGS* | $13,438 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $13,438 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Water Disposal | Personnel Changes | Administrative Changes | Electricity Usage | Electricity Demand | Water Disposal | Personnel Changes | Administrative Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | Tgal | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $637 Cost: $945 |
$366 | 9,965 | $271 | 23 | - | - | - | - | - | - |
$366 9,965 kWh |
$271 23 kW-months/year |
- - Tgal |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $395 Cost: $600 |
$338 | 9,086 | $57 | 5 | - | - | - | - | - | - |
$338 9,086 kWh |
$57 5 kW-months/year |
- - Tgal |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $305 Cost: $100 |
$305 | 8,206 | - | - | - | - | - | - | - | - |
$305 8,206 kWh |
- - kW-months/year |
- - Tgal |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4314 USE SYNTHETIC LUBRICANT |
Savings: $191 Cost: $150 |
$134 | 3,517 | $57 | 5 | - | - | - | - | - | - |
$134 3,517 kWh |
$57 5 kW-months/year |
- - Tgal |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 3.5313 INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE |
Savings: $4,287 Cost: $1,525 |
- | - | - | - | - | - | - | - | $4,287 | - |
- - kWh |
- - kW-months/year |
- - Tgal |
- - $ |
$4,287 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 3.5313 INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE |
Savings: $3,425 Cost: $400 |
- | - | - | - | - | - | - | - | $3,425 | - |
- - kWh |
- - kW-months/year |
- - Tgal |
- - $ |
$3,425 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 3.4151 MINIMIZE WATER USAGE |
Savings: $823 Cost: $1,125 |
- | - | - | - | $823 | 139,230 | - | - | - | - |
- - kWh |
- - kW-months/year |
$823 139,230 Tgal |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 4.652 REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES |
Savings: $3,375 Cost: $4,395 |
$(-312) | (-8,499) | $(-213) | (-19) | - | - | $3,900 | - | - | - |
$(-312) (-8,499) kWh |
$(-213) (-19) kW-months/year |
- - Tgal |
$3,900 - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $13,438 Cost: $9,240 |
$831 | 22,275 | $172 | 14 | $823 | 139,230 | $3,900 | - | $7,712 | - | $831 22,275 kWh |
$172 14 kW-months/year |
$823 139,230 Tgal |
$3,900 - $ |
$7,712 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $13,438 Cost: $9,240 |
$831 | 22,275 | $172 | 14 | $823 | 139,230 | $3,900 | - | $7,712 | - | $831 22,275 kWh |
$172 14 kW-months/year |
$823 139,230 Tgal |
$3,900 - $ |
$7,712 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | Tgal | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Water Disposal | Personnel Changes | Administrative Changes | Electricity Usage | Electricity Demand | Water Disposal | Personnel Changes | Administrative Changes |