Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Bradley University |
---|---|
Assessment Year | 1998 |
Principal Product | Fiberglass Boats |
NAICS | n/a |
SIC | 3732 - Boat Building And Repairing |
Sales | $1,000,000-$5,000,000 |
# of Employees | 35 |
Plant Area (Sq.Ft.) | 23,040 |
Annual Production | 75 Pieces |
Production Hrs. Annual | 2,340 |
Location (State) | IL |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $27,820 | 447,245 | kWh | $0.06 |
Electricity Demand | $5,355 | 2,142 | kW-months/year | $2.50 |
Electricity Fees | $1,182 | - | $ | - |
Natural Gas | $6,260 | 1,207 | MMBtu | $5.19 |
TOTAL ENERGY COSTS | $41,937 | |||
RECOMMENDED SAVINGS* | $54,868 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $1,296 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Administrative Changes | Primary Raw Material | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Administrative Changes | Primary Raw Material | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | Tgal | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $3,566 Cost: $5,590 |
$1,414 | 36,049 | $1,584 | 151 | - | - | - | - | $568 | - | - | - |
$1,414 36,049 kWh |
$1,584 151 kW-months/year |
- - MMBtu |
- - Tgal |
$568 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.1311 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT |
Savings: $2,573 Cost: $3,500 |
$3,153 | 95,545 | $1,051 | 326 | $(-1,631) | (-363) | - | - | - | - | - | - |
$3,153 95,545 kWh |
$1,051 326 kW-months/year |
$(-1,631) (-363) MMBtu |
- - Tgal |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4224 UPGRADE CONTROLS ON COMPRESSORS |
Savings: $1,788 Cost: $1,500 |
$894 | 22,860 | $894 | 108 | - | - | - | - | - | - | - | - |
$894 22,860 kWh |
$894 108 kW-months/year |
- - MMBtu |
- - Tgal |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $763 Cost: $200 |
$338 | 8,499 | $425 | 41 | - | - | - | - | - | - | - | - |
$338 8,499 kWh |
$425 41 kW-months/year |
- - MMBtu |
- - Tgal |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $714 Cost: $400 |
$343 | 8,792 | $371 | 35 | - | - | - | - | - | - | - | - |
$343 8,792 kWh |
$371 35 kW-months/year |
- - MMBtu |
- - Tgal |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4314 USE SYNTHETIC LUBRICANT |
Savings: $555 Cost: $300 |
$246 | 6,155 | $309 | 30 | - | - | - | - | - | - | - | - |
$246 6,155 kWh |
$309 30 kW-months/year |
- - MMBtu |
- - Tgal |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 3.2123 CONVERT TO HIGH VOLUME LOW PRESSURE (HVLP) PAINT GUNS |
Savings: $44,117 Cost: $14,500 |
- | - | - | - | - | - | - | - | - | - | $44,117 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - Tgal |
- - $ |
$44,117 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 3.4151 MINIMIZE WATER USAGE |
Savings: $259 Cost: $620 |
- | - | - | - | - | - | $259 | 39,312 | - | - | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$259 39,312 Tgal |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 4.821 PAY BILLS ON TIME TO AVOID LATE FEES |
Savings: $533 Cost: - |
- | - | - | - | - | - | - | - | $533 | - | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - Tgal |
$533 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $54,868 Cost: $26,610 |
$6,388 | 177,900 | $4,634 | 691 | $(-1,631) | (-363) | $259 | 39,312 | $1,101 | - | $44,117 | - | $6,388 177,900 kWh |
$4,634 691 kW-months/year |
$(-1,631) (-363) MMBtu |
$259 39,312 Tgal |
$1,101 - $ |
$44,117 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $1,296 Cost: $200 |
$338 | 8,499 | $425 | 41 | - | - | - | - | $533 | - | - | - | $338 8,499 kWh |
$425 41 kW-months/year |
- - MMBtu |
- - Tgal |
$533 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | Tgal | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Administrative Changes | Primary Raw Material | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Administrative Changes | Primary Raw Material |