Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Bradley University
Assessment Year 2000
Principal Product Metal storage Buildings
NAICS n/a
SIC 3448 - Prefabricated Metal Buildings
Sales $50,000,000-$100,000,000
# of Employees 270
Plant Area (Sq.Ft.) 300,000
Annual Production 450,000 Units
Production Hrs. Annual 4,320
Location (State) Il
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $226,140 3,521,395 kWh $0.06
Electricity Fees $11,089 - $ -
Natural Gas $65,693 15,550 MMBtu $4.22
TOTAL ENERGY COSTS $308,836
RECOMMENDED SAVINGS* $26,501 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $17,118
#|Description Savings
Cost
Status Electricity Usage Water Disposal Other Liquid (non-haz) Administrative Changes Ancillary Material Cost Primary Product Electricity Usage Water Disposal Other Liquid (non-haz) Administrative Changes Ancillary Material Cost Primary Product
$ kWh $ Tgal $ gal $ $ $ $ $ $
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$7,555
Cost:
$13,420
$7,555 117,819 - - - - - - - - - - $7,555
117,819
kWh
-
-
Tgal
-
-
gal
-
-
$
-
-
$
-
-
$
02: 2.7135 INSTALL OCCUPANCY SENSORS Savings:
$3,918
Cost:
$930
$3,918 60,961 - - - - - - - - - - $3,918
60,961
kWh
-
-
Tgal
-
-
gal
-
-
$
-
-
$
-
-
$
03: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS Savings:
$3,648
Cost:
$1,125
$3,648 53,634 - - - - - - - - - - $3,648
53,634
kWh
-
-
Tgal
-
-
gal
-
-
$
-
-
$
-
-
$
04: 2.7133 USE SEPARATE SWITCHES ON PERIMETER LIGHTING WHICH MAY BE TURNED OFF WHEN NATURAL LIGHT IS AVAILABLE Savings:
$826
Cost:
-
$826 12,896 - - - - - - - - - - $826
12,896
kWh
-
-
Tgal
-
-
gal
-
-
$
-
-
$
-
-
$
05: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$245
Cost:
$235
$149 2,345 - - - - - - $56 - $40 - $149
2,345
kWh
-
-
Tgal
-
-
gal
-
-
$
$56
-
$
$40
-
$
06: 3.6114 USE PRECIPITATING AGENTS IN WASTE WATER TREATMENT THAT PRODUCE THE LEAST QUANTITY OF WASTE Savings:
$1,494
Cost:
$4,825
- - $1,494 1,350 - - - - - - - - -
-
kWh
$1,494
1,350
Tgal
-
-
gal
-
-
$
-
-
$
-
-
$
07: 3.7211 MODIFY MATERIAL APPLICATION METHODS Savings:
$1,171
Cost:
$1,500
- - - - $1,171 15 - - - - - - -
-
kWh
-
-
Tgal
$1,171
15
gal
-
-
$
-
-
$
-
-
$
08: 4.4470 AUTOMATE PAYROLL SYSTEM Savings:
$7,644
Cost:
$7,000
- - - - - - $7,644 - - - - - -
-
kWh
-
-
Tgal
-
-
gal
$7,644
-
$
-
-
$
-
-
$
TOTAL RECOMMENDED Savings:
$26,501
Cost:
$29,035
$16,096 247,655 $1,494 1,350 $1,171 15 $7,644 - $56 - $40 - $16,096
247,655
kWh
$1,494
1,350
Tgal
$1,171
15
gal
$7,644
-
$
$56
-
$
$40
-
$
TOTAL IMPLEMENTED Savings:
$17,118
Cost:
$16,975
$15,947 245,310 - - $1,171 15 - - - - - - $15,947
245,310
kWh
-
-
Tgal
$1,171
15
gal
-
-
$
-
-
$
-
-
$
Savings
Cost
$ kWh $ Tgal $ gal $ $ $ $ $ $
Electricity Usage Water Disposal Other Liquid (non-haz) Administrative Changes Ancillary Material Cost Primary Product Electricity Usage Water Disposal Other Liquid (non-haz) Administrative Changes Ancillary Material Cost Primary Product