Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Bradley University |
---|---|
Assessment Year | 2001 |
Principal Product | Electrical Control Panels and Mobile Generator Sets |
NAICS | n/a |
SIC | 3559 - Special Industry Machinery, Nec |
Sales | $10,000,000-$50,000,000 |
# of Employees | 181 |
Plant Area (Sq.Ft.) | 130,560 |
Annual Production | 525 Pieces |
Production Hrs. Annual | 2,730 |
Location (State) | IL |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $72,154 | 1,057,648 | kWh | $0.07 |
Electricity Demand | $10,364 | 4,350 | kW-months/year | $2.38 |
Electricity Fees | $463 | - | $ | - |
Natural Gas | $84,799 | 9,820 | MMBtu | $8.64 |
TOTAL ENERGY COSTS | $170,958 | |||
RECOMMENDED SAVINGS* | $55,113 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $1,240 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Administrative Changes | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Administrative Changes | One-time Revenue or Avoided Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | Tgal | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7231 USE RADIANT HEATER FOR SPOT HEATING |
Savings: $19,999 Cost: $78,750 |
- | - | - | - | $19,999 | 2,378 | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$19,999 2,378 MMBtu |
- - Tgal |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7111 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS |
Savings: $1,751 Cost: $3,000 |
$1,248 | 18,299 | $447 | 188 | - | - | - | - | - | - | $56 | - |
$1,248 18,299 kWh |
$447 188 kW-months/year |
- - MMBtu |
- - Tgal |
- - $ |
$56 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $1,505 Cost: $2,025 |
$1,209 | 17,734 | $296 | 124 | - | - | - | - | - | - | - | - |
$1,209 17,734 kWh |
$296 124 kW-months/year |
- - MMBtu |
- - Tgal |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $167 Cost: $253 |
$159 | 2,330 | $8 | 3 | - | - | - | - | - | - | - | - |
$159 2,330 kWh |
$8 3 kW-months/year |
- - MMBtu |
- - Tgal |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $223 Cost: - |
$188 | 2,751 | $35 | 15 | - | - | - | - | - | - | - | - |
$188 2,751 kWh |
$35 15 kW-months/year |
- - MMBtu |
- - Tgal |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $188 Cost: $500 |
$159 | 2,331 | $29 | 13 | - | - | - | - | - | - | - | - |
$159 2,331 kWh |
$29 13 kW-months/year |
- - MMBtu |
- - Tgal |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $145 Cost: $300 |
$122 | 1,790 | $23 | 10 | - | - | - | - | - | - | - | - |
$122 1,790 kWh |
$23 10 kW-months/year |
- - MMBtu |
- - Tgal |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 3.4151 MINIMIZE WATER USAGE |
Savings: $1,095 Cost: $1,035 |
- | - | - | - | - | - | $1,095 | 210,600 | - | - | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$1,095 210,600 Tgal |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 4.231 PURCHASE EQUIPMENT INSTEAD OF LEASING |
Savings: $18,000 Cost: $50,000 |
- | - | - | - | - | - | - | - | - | - | $18,000 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - Tgal |
- - $ |
$18,000 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 4.231 PURCHASE EQUIPMENT INSTEAD OF LEASING |
Savings: $10,800 Cost: $20,000 |
- | - | - | - | - | - | - | - | - | - | $10,800 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - Tgal |
- - $ |
$10,800 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
11: 4.447 AUTOMATE PAYROLL SYSTEM |
Savings: $1,240 Cost: $1,400 |
- | - | - | - | - | - | - | - | $1,240 | - | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - Tgal |
$1,240 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $55,113 Cost: $157,263 |
$3,085 | 45,235 | $838 | 353 | $19,999 | 2,378 | $1,095 | 210,600 | $1,240 | - | $28,856 | - | $3,085 45,235 kWh |
$838 353 kW-months/year |
$19,999 2,378 MMBtu |
$1,095 210,600 Tgal |
$1,240 - $ |
$28,856 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $1,240 Cost: $1,400 |
- | - | - | - | - | - | - | - | $1,240 | - | - | - | - - kWh |
- - kW-months/year |
- - MMBtu |
- - Tgal |
$1,240 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | Tgal | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Administrative Changes | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Administrative Changes | One-time Revenue or Avoided Cost |