Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Bradley University |
---|---|
Assessment Year | 2006 |
Principal Product | Wooden Carts, Boxes, Pallets |
NAICS | 238130 - Framing Contractors |
SIC | 2448 - Wood Pallets And Skids |
Sales | $10,000,000-$50,000,000 |
# of Employees | 61 |
Plant Area (Sq.Ft.) | 102,000 |
Annual Production | 350 Pieces |
Production Hrs. Annual | 5,304 |
Location (State) | IL |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $48,335 | 958,860 | kWh | $0.05 |
Electricity Demand | $12,814 | 1,745 | kW-months/year | $7.34 |
Natural Gas | $21,427 | 2,373 | MMBtu | $9.03 |
TOTAL ENERGY COSTS | $82,576 | |||
RECOMMENDED SAVINGS* | $19,378 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $6,189 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Electricity Usage | Electricity Demand | Natural Gas | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7231 USE RADIANT HEATER FOR SPOT HEATING |
Savings: $9,279 Cost: $8,400 |
- | - | - | - | $9,279 | 1,067 |
- - kWh |
- - kW-months/year |
$9,279 1,067 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4113 INSTALL MOTOR VOLTAGE CONTROLLER ON LIGHTLY LOADED MOTORS |
Savings: $2,839 Cost: $4,020 |
$2,246 | 152 | $593 | 81 | - | - |
$2,246 152 kWh |
$593 81 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $2,511 Cost: $1,500 |
$1,862 | 126 | $649 | 88 | - | - |
$1,862 126 kWh |
$649 88 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT |
Savings: $2,403 Cost: $400 |
- | - | - | - | $2,403 | 230 |
- - kWh |
- - kW-months/year |
$2,403 230 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4314 USE SYNTHETIC LUBRICANT |
Savings: $1,275 Cost: $1,500 |
$759 | 51 | $516 | 70 | - | - |
$759 51 kWh |
$516 70 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7134 USE PHOTOCELL CONTROLS |
Savings: $903 Cost: $2,000 |
$492 | 33 | $411 | 56 | - | - |
$492 33 kWh |
$411 56 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $168 Cost: $225 |
$140 | 10 | $28 | 4 | - | - |
$140 10 kWh |
$28 4 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $19,378 Cost: $18,045 |
$5,499 | 372 | $2,197 | 299 | $11,682 | 1,297 | $5,499 372 kWh |
$2,197 299 kW-months/year |
$11,682 1,297 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $6,189 Cost: $3,400 |
$2,621 | 177 | $1,165 | 158 | $2,403 | 230 | $2,621 177 kWh |
$1,165 158 kW-months/year |
$2,403 230 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Electricity Usage | Electricity Demand | Natural Gas |