Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Bradley University |
---|---|
Assessment Year | 2007 |
Principal Product | Newsprint |
NAICS | 424110 - Printing and Writing Paper Merchant Wholesalers |
SIC | 2711 - Newspapers |
Sales | $10,000,000-$50,000,000 |
# of Employees | 217 |
Plant Area (Sq.Ft.) | 70,000 |
Annual Production | 5,000 Tons |
Production Hrs. Annual | 8,760 |
Location (State) | IL |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $160,386 | 3,169,510 | kWh | $0.05 |
Natural Gas | $12,785 | 1,845 | MMBtu | $6.93 |
TOTAL ENERGY COSTS | $173,171 | |||
RECOMMENDED SAVINGS* | $20,197 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $2,486 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Water Disposal | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | Water Disposal | One-time Revenue or Avoided Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | Tgal | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7447 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS |
Savings: $7,446 Cost: $2,400 |
$7,446 | 878 | - | - | - | - | - | - |
$7,446 878 kWh |
- - kW-months/year |
- - Tgal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7447 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS |
Savings: $4,262 Cost: $14,000 |
$612 | 72 | - | - | - | - | $3,650 | - |
$612 72 kWh |
- - kW-months/year |
- - Tgal |
$3,650 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7134 USE PHOTOCELL CONTROLS |
Savings: $1,823 Cost: $90 |
$878 | 47 | $1 | 43 | - | - | $944 | - |
$878 47 kWh |
$1 43 kW-months/year |
- - Tgal |
$944 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $1,358 Cost: $2,109 |
$1,357 | 91 | $1 | 37 | - | - | - | - |
$1,357 91 kWh |
$1 37 kW-months/year |
- - Tgal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $1,328 Cost: $150 |
$1,328 | 78 | - | - | - | - | - | - |
$1,328 78 kWh |
- - kW-months/year |
- - Tgal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $498 Cost: $585 |
$354 | 23 | - | - | - | - | $144 | - |
$354 23 kWh |
- - kW-months/year |
- - Tgal |
$144 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $1,183 Cost: $2,730 |
$1,183 | 79 | - | - | - | - | - | - |
$1,183 79 kWh |
- - kW-months/year |
- - Tgal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $1,128 Cost: $500 |
$1,127 | 66 | $1 | 31 | - | - | - | - |
$1,127 66 kWh |
$1 31 kW-months/year |
- - Tgal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 3.4151 MINIMIZE WATER USAGE |
Savings: $1,171 Cost: $4,000 |
- | - | - | - | $1,171 | 219,000 | - | - |
- - kWh |
- - kW-months/year |
$1,171 219,000 Tgal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $20,197 Cost: $26,564 |
$14,285 | 1,334 | $3 | 111 | $1,171 | 219,000 | $4,738 | - | $14,285 1,334 kWh |
$3 111 kW-months/year |
$1,171 219,000 Tgal |
$4,738 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $2,486 Cost: $2,609 |
$2,484 | 157 | $2 | 68 | - | - | - | - | $2,484 157 kWh |
$2 68 kW-months/year |
- - Tgal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | Tgal | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Water Disposal | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | Water Disposal | One-time Revenue or Avoided Cost |