Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Bradley University |
---|---|
Assessment Year | 2012 |
Principal Product | Steel Wire and Agricultural Fencing |
NAICS | 331222 - Steel Wire Drawing |
SIC | 3315 - Steel Wire And Related Products |
Sales | $100,000,000-$500,000,000 |
# of Employees | 420 |
Plant Area (Sq.Ft.) | 870,000 |
Annual Production | 120,000 Tons |
Production Hrs. Annual | 6,240 |
Location (State) | IL |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $2,821,933 | 84,283,144 | kWh | $0.03 |
Electricity Demand | $1,238 | 154,738 | kW-months/year | $0.01 |
Electricity Fees | $37,434 | - | $ | - |
Natural Gas | $1,809,657 | 548,727 | MMBtu | $3.30 |
TOTAL ENERGY COSTS | $4,670,262 | |||
RECOMMENDED SAVINGS* | $379,570 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $263,891 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Ancillary Material Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.2136 INSTALL / REPAIR INSULATION ON STEAM LINES |
Savings: $147,427 Cost: $200,000 |
- | - | - | - | $147,427 | 45,057 | - | - | - | - |
- - kWh |
- - kW-months/year |
$147,427 45,057 MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $64,077 Cost: $313,924 |
$64,048 | 1,911,879 | $29 | 3,677 | - | - | - | - | - | - |
$64,048 1,911,879 kWh |
$29 3,677 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7231 USE RADIANT HEATER FOR SPOT HEATING |
Savings: $60,134 Cost: $105,100 |
- | - | - | - | $60,134 | 18,378 | - | - | - | - |
- - kWh |
- - kW-months/year |
$60,134 18,378 MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT |
Savings: $26,689 Cost: $30,000 |
- | - | - | - | $26,689 | 8,157 | - | - | - | - |
- - kWh |
- - kW-months/year |
$26,689 8,157 MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.1221 REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES |
Savings: $23,015 Cost: $48,000 |
- | - | - | - | $23,015 | 7,034 | - | - | - | - |
- - kWh |
- - kW-months/year |
$23,015 7,034 MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7134 USE PHOTOCELL CONTROLS |
Savings: $18,400 Cost: $14,100 |
$18,385 | 548,846 | $15 | 1,830 | - | - | - | - | - | - |
$18,385 548,846 kWh |
$15 1,830 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT |
Savings: $5,842 Cost: $6,000 |
$(-20) | (-608) | $(0) | (-4) | $5,862 | 1,791 | - | - | - | - |
$(-20) (-608) kWh |
$(0) (-4) kW-months/year |
$5,862 1,791 MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $5,441 Cost: $600 |
$5,439 | 162,359 | $2 | 233 | - | - | - | - | - | - |
$5,439 162,359 kWh |
$2 233 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.7145 INSTALL SKYLIGHTS |
Savings: $5,048 Cost: $12,215 |
$5,048 | 150,696 | - | - | - | - | - | - | - | - |
$5,048 150,696 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $3,117 Cost: $20 |
$3,116 | 93,007 | $1 | 107 | - | - | - | - | - | - |
$3,116 93,007 kWh |
$1 107 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
11: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $2,653 Cost: $1,200 |
$2,652 | 79,169 | $1 | 124 | - | - | - | - | - | - |
$2,652 79,169 kWh |
$1 124 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
12: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $2,527 Cost: $500 |
$2,526 | 75,411 | $1 | 145 | - | - | - | - | - | - |
$2,526 75,411 kWh |
$1 145 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
13: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT |
Savings: $1,210 Cost: $1,500 |
- | - | - | - | $1,210 | 370 | - | - | - | - |
- - kWh |
- - kW-months/year |
$1,210 370 MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
14: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $1,121 Cost: $1,225 |
$502 | 14,980 | $0 | 21 | - | - | $259 | - | $360 | - |
$502 14,980 kWh |
$0 21 kW-months/year |
- - MMBtu |
$259 - $ |
$360 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
15: 4.423 MOVE PRODUCT USING MECHANICAL MEANS |
Savings: $12,870 Cost: $20,000 |
- | - | - | - | - | - | $12,870 | - | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$12,870 - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $379,570 Cost: $754,384 |
$101,695 | 3,035,739 | $49 | 6,133 | $264,337 | 80,787 | $13,129 | - | $360 | - | $101,695 3,035,739 kWh |
$49 6,133 kW-months/year |
$264,337 80,787 MMBtu |
$13,129 - $ |
$360 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $263,891 Cost: $565,284 |
$101,716 | 3,036,347 | $49 | 6,137 | $148,637 | 45,427 | $13,129 | - | $360 | - | $101,716 3,036,347 kWh |
$49 6,137 kW-months/year |
$148,637 45,427 MMBtu |
$13,129 - $ |
$360 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Ancillary Material Cost |