Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Bradley University |
---|---|
Assessment Year | 2012 |
Principal Product | Uncoated recycled paperboard |
NAICS | 322130 - Paperboard Mills |
SIC | 2631 - Paperboard Mills |
Sales | $1,000,000-$5,000,000 |
# of Employees | 46 |
Plant Area (Sq.Ft.) | 87,500 |
Annual Production | 42,000 Tons |
Production Hrs. Annual | 8,712 |
Location (State) | IL |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $826,142 | 20,195,095 | kWh | $0.04 |
Electricity Demand | $98,952 | 32,369 | kW-months/year | $3.06 |
Electricity Fees | $14,259 | - | $ | - |
Natural Gas | $767,205 | 213,487 | MMBtu | $3.59 |
TOTAL ENERGY COSTS | $1,706,558 | |||
RECOMMENDED SAVINGS* | $30,571 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $16,802 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Ancillary Material Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $13,031 Cost: $31,529 |
$11,820 | 288,990 | $1,211 | 396 | - | - | - | - | - | - |
$11,820 288,990 kWh |
$1,211 396 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.1213 DIRECT WARMEST AIR TO COMBUSTION INTAKE |
Savings: $10,810 Cost: $14,000 |
- | - | - | - | $10,810 | 3,113 | - | - | - | - |
- - kWh |
- - kW-months/year |
$10,810 3,113 MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $2,421 Cost: $7,300 |
$2,196 | 53,677 | $225 | 74 | - | - | - | - | - | - |
$2,196 53,677 kWh |
$225 74 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $929 Cost: $1,200 |
$770 | 18,819 | $159 | 52 | - | - | - | - | - | - |
$770 18,819 kWh |
$159 52 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4314 USE SYNTHETIC LUBRICANT |
Savings: $849 Cost: $500 |
$770 | 18,821 | $79 | 26 | - | - | - | - | - | - |
$770 18,821 kWh |
$79 26 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $820 Cost: $20 |
$744 | 18,193 | $76 | 25 | - | - | - | - | - | - |
$744 18,193 kWh |
$76 25 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $648 Cost: $220 |
$588 | 14,377 | $60 | 20 | - | - | - | - | - | - |
$588 14,377 kWh |
$60 20 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $642 Cost: $600 |
$308 | 7,323 | $31 | 10 | - | - | $127 | - | $176 | - |
$308 7,323 kWh |
$31 10 kW-months/year |
- - MMBtu |
$127 - $ |
$176 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.2136 INSTALL / REPAIR INSULATION ON STEAM LINES |
Savings: $421 Cost: $700 |
- | - | - | - | $421 | 117 | - | - | - | - |
- - kWh |
- - kW-months/year |
$421 117 MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $30,571 Cost: $56,069 |
$17,196 | 420,200 | $1,841 | 602 | $11,231 | 3,230 | $127 | - | $176 | - | $17,196 420,200 kWh |
$1,841 602 kW-months/year |
$11,231 3,230 MMBtu |
$127 - $ |
$176 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $16,802 Cost: $40,729 |
$14,786 | 361,486 | $1,595 | 521 | $421 | 117 | - | - | - | - | $14,786 361,486 kWh |
$1,595 521 kW-months/year |
$421 117 MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Ancillary Material Cost |