Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Bradley University |
---|---|
Assessment Year | 2013 |
Principal Product | Fabricated light steel products |
NAICS | 332322 - Sheet Metal Work Manufacturing |
SIC | 3444 - Sheet Metalwork |
Sales | $1,000,000-$5,000,000 |
# of Employees | 19 |
Plant Area (Sq.Ft.) | 35,440 |
Annual Production | 1 Units |
Production Hrs. Annual | 1,768 |
Location (State) | IL |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $35,595 | 558,701 | kWh | $0.06 |
Electricity Demand | $10,161 | 3,126 | kW-months/year | $3.25 |
Electricity Fees | $2,766 | - | $ | - |
Natural Gas | $15,000 | 2,241 | MMBtu | $6.69 |
TOTAL ENERGY COSTS | $64,464 | |||
RECOMMENDED SAVINGS* | $16,656 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $4,500 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Ancillary Material Cost | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Ancillary Material Cost | One-time Revenue or Avoided Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7231 USE RADIANT HEATER FOR SPOT HEATING |
Savings: $7,450 Cost: $22,500 |
- | - | - | - | $7,450 | 1,151 | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$7,450 1,151 MMBtu |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7134 USE PHOTOCELL CONTROLS |
Savings: $2,289 Cost: $200 |
$343 | 5,381 | $288 | 89 | - | - | $1,624 | - | $34 | - | - | - |
$343 5,381 kWh |
$288 89 kW-months/year |
- - MMBtu |
$1,624 - $ |
$34 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $1,001 Cost: $3,520 |
$718 | 11,267 | $249 | 77 | - | - | - | - | $34 | - | - | - |
$718 11,267 kWh |
$249 77 kW-months/year |
- - MMBtu |
- - $ |
$34 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $741 Cost: $25 |
$570 | 8,995 | $171 | 53 | - | - | - | - | - | - | - | - |
$570 8,995 kWh |
$171 53 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $397 Cost: $200 |
$397 | 6,232 | - | - | - | - | - | - | - | - | - | - |
$397 6,232 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $278 Cost: $600 |
$207 | 3,247 | $71 | 22 | - | - | - | - | - | - | - | - |
$207 3,247 kWh |
$71 22 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 4.322 ELIMINATE OLD STOCK AND MODIFY INVENTORY CONTROL |
Savings: $4,500 Cost: $10,000 |
- | - | - | - | - | - | - | - | - | - | $4,500 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
$4,500 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $16,656 Cost: $37,045 |
$2,235 | 35,122 | $779 | 240 | $7,450 | 1,151 | $1,624 | - | $68 | - | $4,500 | - | $2,235 35,122 kWh |
$779 240 kW-months/year |
$7,450 1,151 MMBtu |
$1,624 - $ |
$68 - $ |
$4,500 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $4,500 Cost: $10,000 |
- | - | - | - | - | - | - | - | - | - | $4,500 | - | - - kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
$4,500 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Ancillary Material Cost | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Ancillary Material Cost | One-time Revenue or Avoided Cost |