IAC logo
IAC Assessment: BD0430
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: BD0430
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Bradley University
Assessment Year 2013
Principal Product Fabricated light steel products
NAICS 332322 - Sheet Metal Work Manufacturing
SIC 3444 - Sheet Metalwork
Sales $1,000,000-$5,000,000
# of Employees 19
Plant Area (Sq.Ft.) 35,440
Annual Production 1 Units
Production Hrs. Annual 1,768
Location (State) IL
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $35,595 558,701 kWh $0.06
Electricity Demand $10,161 3,126 kW-months/year $3.25
Electricity Fees $2,766 - $ -
Natural Gas $15,000 2,241 MMBtu $6.69
TOTAL ENERGY COSTS $64,464
RECOMMENDED SAVINGS* $16,656 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $4,500
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Natural Gas Personnel Changes Ancillary Material Cost One-time Revenue or Avoided Cost Electricity Usage Electricity Demand Natural Gas Personnel Changes Ancillary Material Cost One-time Revenue or Avoided Cost
$ kWh $ kW-months/year $ MMBtu $ $ $ $ $ $
01: 2.7231 USE RADIANT HEATER FOR SPOT HEATING Savings:
$7,450
Cost:
$22,500
- - - - $7,450 1,151 - - - - - - -
-
kWh
-
-
kW-months/year
$7,450
1,151
MMBtu
-
-
$
-
-
$
-
-
$
02: 2.7134 USE PHOTOCELL CONTROLS Savings:
$2,289
Cost:
$200
$343 5,381 $288 89 - - $1,624 - $34 - - - $343
5,381
kWh
$288
89
kW-months/year
-
-
MMBtu
$1,624
-
$
$34
-
$
-
-
$
03: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$1,001
Cost:
$3,520
$718 11,267 $249 77 - - - - $34 - - - $718
11,267
kWh
$249
77
kW-months/year
-
-
MMBtu
-
-
$
$34
-
$
-
-
$
04: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED Savings:
$741
Cost:
$25
$570 8,995 $171 53 - - - - - - - - $570
8,995
kWh
$171
53
kW-months/year
-
-
MMBtu
-
-
$
-
-
$
-
-
$
05: 2.7135 INSTALL OCCUPANCY SENSORS Savings:
$397
Cost:
$200
$397 6,232 - - - - - - - - - - $397
6,232
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
$
-
-
$
-
-
$
06: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS Savings:
$278
Cost:
$600
$207 3,247 $71 22 - - - - - - - - $207
3,247
kWh
$71
22
kW-months/year
-
-
MMBtu
-
-
$
-
-
$
-
-
$
07: 4.322 ELIMINATE OLD STOCK AND MODIFY INVENTORY CONTROL Savings:
$4,500
Cost:
$10,000
- - - - - - - - - - $4,500 - -
-
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
$
-
-
$
$4,500
-
$
TOTAL RECOMMENDED Savings:
$16,656
Cost:
$37,045
$2,235 35,122 $779 240 $7,450 1,151 $1,624 - $68 - $4,500 - $2,235
35,122
kWh
$779
240
kW-months/year
$7,450
1,151
MMBtu
$1,624
-
$
$68
-
$
$4,500
-
$
TOTAL IMPLEMENTED Savings:
$4,500
Cost:
$10,000
- - - - - - - - - - $4,500 - -
-
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
$
-
-
$
$4,500
-
$
Savings
Cost
$ kWh $ kW-months/year $ MMBtu $ $ $ $ $ $
Electricity Usage Electricity Demand Natural Gas Personnel Changes Ancillary Material Cost One-time Revenue or Avoided Cost Electricity Usage Electricity Demand Natural Gas Personnel Changes Ancillary Material Cost One-time Revenue or Avoided Cost