IAC Center | Boise State University |
---|---|
Assessment Year | 2018 |
Principal Product | Lumber |
NAICS | 333249 - Other Industrial Machinery Manufacturing |
SIC | 2439 - Structural Wood Members, Nec |
Sales | $10,000,000-$50,000,000 |
# of Employees | 165 |
Plant Area (Sq.Ft.) | 426,000 |
Annual Production | 94,000 Thousand Feet |
Production Hrs. Annual | 4,320 |
Location (State) | ID |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $508,570 | 15,892,800 | kWh | $0.03 |
Electricity Demand | $248,892 | 35,556 | kW-months/year | $7.00 |
Electricity Fees | $3,777 | - | $ | - |
Wood | $282,720 | 339,261 | MMBtu | $0.83 |
TOTAL ENERGY COSTS | $1,043,958 | |||
RECOMMENDED SAVINGS* | $98,452 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | - |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Wood | Water Usage | Electricity Usage | Electricity Demand | Wood | Water Usage | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | Tgal | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.2121 INCREASE AMOUNT OF CONDENSATE RETURNED |
Savings: $91,034 Cost: $31,760 |
- | - | - | - | $215 | 258 | $90,819 | 1,297,416 |
- - kWh |
- - kW-months/year |
$215 258 MMBtu |
$90,819 1,297,416 Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $5,461 Cost: $1,350 |
$3,844 | 120,120 | $1,617 | 231 | - | - | - | - |
$3,844 120,120 kWh |
$1,617 231 kW-months/year |
- - MMBtu |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $855 Cost: $20 |
$602 | 18,813 | $253 | 36 | - | - | - | - |
$602 18,813 kWh |
$253 36 kW-months/year |
- - MMBtu |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $577 Cost: $138 |
$577 | 18,042 | - | - | - | - | - | - |
$577 18,042 kWh |
- - kW-months/year |
- - MMBtu |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $525 Cost: $2,420 |
$370 | 11,550 | $155 | 22 | - | - | - | - |
$370 11,550 kWh |
$155 22 kW-months/year |
- - MMBtu |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $98,452 Cost: $35,688 |
$5,392 | 168,525 | $2,025 | 289 | $215 | 258 | $90,819 | 1,297,416 | $5,392 168,525 kWh |
$2,025 289 kW-months/year |
$215 258 MMBtu |
$90,819 1,297,416 Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: - Cost: - |
- | - | - | - | - | - | - | - | - - kWh |
- - kW-months/year |
- - MMBtu |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | Tgal | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Wood | Water Usage | Electricity Usage | Electricity Demand | Wood | Water Usage |