IAC logo
IAC Assessment: CI0022
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: CI0022
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of California, Irvine
Assessment Year 2023
Principal Product Soy Products
NAICS 311991 - Perishable Prepared Food Manufacturing
SIC 2099 - Food Preparations, Nec
Sales $10,000,000-$50,000,000
# of Employees 45
Plant Area (Sq.Ft.) 25,000
Annual Production 3,000,000 Pounds
Production Hrs. Annual 6,240
Location (State) CA
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $64,753 419,136 kWh $0.15
Electricity Demand $27,962 1,768 kW-months/year $15.82
Electricity Fees $12,920 - $ -
Natural Gas $36,451 2,161 MMBtu $16.87
LPG $22,550 2,000 MMBtu $11.28
TOTAL ENERGY COSTS $165,316
RECOMMENDED SAVINGS* $101,280 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* -
#|Description Savings
Cost
Status Electricity Usage Electricity Demand LPG Electricity Usage Electricity Demand LPG
$ kWh $ kW-months/year $ MMBtu
01: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY Savings:
$30,795
Cost:
$185,422
$26,697 172,800 $4,098 259 - - $26,697
172,800
kWh
$4,098
259
kW-months/year
-
-
MMBtu
02: 2.1321 REPLACE FOSSIL FUEL EQUIPMENT WITH ELECTRICAL EQUIPMENT Savings:
$18,385
Cost:
$60,000
$(-4,165) (-26,957) - - $22,550 2,000 $(-4,165)
(-26,957)
kWh
-
-
kW-months/year
$22,550
2,000
MMBtu
03: 2.2442 PREHEAT COMBUSTION AIR WITH WASTE HEAT Savings:
$17,839
Cost:
$9,000
$14,408 93,255 $3,431 217 - - $14,408
93,255
kWh
$3,431
217
kW-months/year
-
-
MMBtu
04: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$12,948
Cost:
$300
$11,788 76,296 $1,160 73 - - $11,788
76,296
kWh
$1,160
73
kW-months/year
-
-
MMBtu
05: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE Savings:
$10,784
Cost:
-
$10,784 69,798 - - - - $10,784
69,798
kWh
-
-
kW-months/year
-
-
MMBtu
06: 2.3132 RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS Savings:
$5,312
Cost:
$50
- - $5,312 336 - - -
-
kWh
$5,312
336
kW-months/year
-
-
MMBtu
07: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$3,547
Cost:
$7,400
$2,545 16,472 $1,002 63 - - $2,545
16,472
kWh
$1,002
63
kW-months/year
-
-
MMBtu
08: 2.7135 INSTALL OCCUPANCY SENSORS Savings:
$1,670
Cost:
$1,125
$1,370 8,869 $300 19 - - $1,370
8,869
kWh
$300
19
kW-months/year
-
-
MMBtu
TOTAL RECOMMENDED Savings:
$101,280
Cost:
$263,297
$63,427 410,533 $15,303 968 $22,550 2,000 $63,427
410,533
kWh
$15,303
968
kW-months/year
$22,550
2,000
MMBtu
TOTAL IMPLEMENTED Savings:
-
Cost:
-
- - - - - - -
-
kWh
-
-
kW-months/year
-
-
MMBtu
Savings
Cost
$ kWh $ kW-months/year $ MMBtu
Electricity Usage Electricity Demand LPG Electricity Usage Electricity Demand LPG