IAC logo
IAC Assessment: CI0023
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: CI0023
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of California, Irvine
Assessment Year 2023
Principal Product Grain Based Breakfast Cereals
NAICS 311230 - Breakfast Cereal Manufacturing
SIC 2043 - Cereal Breakfast Foods
Sales $10,000,000-$50,000,000
# of Employees 60
Plant Area (Sq.Ft.) 200,000
Annual Production 12,000,000 Pounds
Production Hrs. Annual 6,240
Location (State) CA
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $210,344 1,517,486 kWh $0.14
Electricity Demand $31,474 4,662 kW-months/year $6.75
Electricity Fees $118,730 - $ -
Natural Gas $115,991 11,599 MMBtu $10.00
TOTAL ENERGY COSTS $477,808
RECOMMENDED SAVINGS* $171,403 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* -
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Natural Gas Increase in Production Electricity Usage Electricity Demand Natural Gas Increase in Production
$ kWh $ kW-months/year $ MMBtu $ %
01: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY Savings:
$78,738
Cost:
$658,288
$72,614 523,908 $6,124 907 - - - - $72,614
523,908
kWh
$6,124
907
kW-months/year
-
-
MMBtu
-
-
%
02: 2.2511 INSULATE BARE EQUIPMENT Savings:
$45,480
Cost:
$17,533
- - - - $45,480 4,548 - - -
-
kWh
-
-
kW-months/year
$45,480
4,548
MMBtu
-
-
%
03: 2.1224 REPLACE BOILER Savings:
$13,894
Cost:
$30,000
$(-29,059) (-209,664) $(-545) (-81) $43,498 4,350 - - $(-29,059)
(-209,664)
kWh
$(-545)
(-81)
kW-months/year
$43,498
4,350
MMBtu
-
-
%
04: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$7,902
Cost:
$300
$7,226 52,136 $676 100 - - - - $7,226
52,136
kWh
$676
100
kW-months/year
-
-
MMBtu
-
-
%
05: 2.7135 INSTALL OCCUPANCY SENSORS Savings:
$7,791
Cost:
$2,625
$7,539 54,395 $252 37 - - - - $7,539
54,395
kWh
$252
37
kW-months/year
-
-
MMBtu
-
-
%
06: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$5,881
Cost:
$2,299
$5,424 39,137 $457 68 - - - - $5,424
39,137
kWh
$457
68
kW-months/year
-
-
MMBtu
-
-
%
07: 2.3132 RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS Savings:
$5,670
Cost:
$7,500
- - $5,670 840 - - - - -
-
kWh
$5,670
840
kW-months/year
-
-
MMBtu
-
-
%
08: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT Savings:
$3,797
Cost:
$5,000
$2,177 15,709 $1,620 240 - - - - $2,177
15,709
kWh
$1,620
240
kW-months/year
-
-
MMBtu
-
-
%
09: 4.652 REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES Savings:
$2,250
Cost:
$13,000
- - - - - - $2,250 - -
-
kWh
-
-
kW-months/year
-
-
MMBtu
$2,250
-
%
TOTAL RECOMMENDED Savings:
$171,403
Cost:
$736,545
$65,921 475,621 $14,254 2,112 $88,978 8,898 $2,250 - $65,921
475,621
kWh
$14,254
2,112
kW-months/year
$88,978
8,898
MMBtu
$2,250
-
%
TOTAL IMPLEMENTED Savings:
-
Cost:
-
- - - - - - - - -
-
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
%
Savings
Cost
$ kWh $ kW-months/year $ MMBtu $ %
Electricity Usage Electricity Demand Natural Gas Increase in Production Electricity Usage Electricity Demand Natural Gas Increase in Production