Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of California, Irvine |
---|---|
Assessment Year | 2024 |
Principal Product | Plastic Sheets |
NAICS | 326130 - Laminated Plastics Plate, Sheet (except Packaging), and Shape Manufacturing |
SIC | 3083 - Laminated Plastics Plate & Sheet |
Sales | $10,000,000-$50,000,000 |
# of Employees | 65 |
Plant Area (Sq.Ft.) | 50,000 |
Annual Production | 18,000,000 Pieces |
Production Hrs. Annual | 2,860 |
Location (State) | CA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $141,802 | 725,452 | kWh | $0.20 |
Electricity Demand | $52,673 | 3,949 | kW-months/year | $13.34 |
Electricity Fees | $12,195 | - | $ | - |
Natural Gas | $119 | 8 | MMBtu | $14.88 |
LPG | $16,020 | 129 | MMBtu | $123.90 |
Other Gas | $207 | 1 | MMBtu | $207.00 |
TOTAL ENERGY COSTS | $230,192 | |||
RECOMMENDED SAVINGS* | $269,854 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | - |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | LPG | Administrative Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | LPG | Administrative Changes | Ancillary Material Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY |
Savings: $149,299 Cost: $539,950 |
$132,491 | 677,703 | $16,808 | 1,260 | - | - | - | - | - | - |
$132,491 677,703 kWh |
$16,808 1,260 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.2511 INSULATE BARE EQUIPMENT |
Savings: $44,112 Cost: $5,943 |
$44,112 | 225,694 | - | - | - | - | - | - | - | - |
$44,112 225,694 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7232 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL |
Savings: $39,711 Cost: $350,000 |
$39,711 | 203,181 | - | - | - | - | - | - | - | - |
$39,711 203,181 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.1321 REPLACE FOSSIL FUEL EQUIPMENT WITH ELECTRICAL EQUIPMENT |
Savings: $13,825 Cost: $8,000 |
$(-1,619) | (-8,280) | $(-576) | (-43) | $16,020 | 129 | - | - | - | - |
$(-1,619) (-8,280) kWh |
$(-576) (-43) kW-months/year |
$16,020 129 MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7232 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL |
Savings: $5,673 Cost: $25,000 |
$5,673 | 29,018 | - | - | - | - | - | - | - | - |
$5,673 29,018 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $5,220 Cost: $200 |
$4,150 | 21,229 | $1,070 | 80 | - | - | - | - | - | - |
$4,150 21,229 kWh |
$1,070 80 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7134 USE PHOTOCELL CONTROLS |
Savings: $4,708 Cost: $27,760 |
$2,254 | 11,531 | $2,161 | 162 | - | - | $117 | - | $176 | - |
$2,254 11,531 kWh |
$2,161 162 kW-months/year |
- - MMBtu |
$117 - $ |
$176 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.7493 USE DOUBLE OR TRIPLE GLAZED WINDOWS TO MAINTAIN HIGHER RELATIVE HUMIDITY AND TO REDUCE HEAT LOSSES |
Savings: $4,255 Cost: $19,000 |
$4,255 | 21,764 | - | - | - | - | - | - | - | - |
$4,255 21,764 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $1,503 Cost: $1,600 |
$1,208 | 6,177 | $295 | 22 | - | - | - | - | - | - |
$1,208 6,177 kWh |
$295 22 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 2.3132 RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS |
Savings: $846 Cost: $50 |
- | - | $846 | 63 | - | - | - | - | - | - |
- - kWh |
$846 63 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
11: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $702 Cost: - |
$546 | 2,794 | $156 | 12 | - | - | - | - | - | - |
$546 2,794 kWh |
$156 12 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $269,854 Cost: $977,503 |
$232,781 | 1,190,811 | $20,760 | 1,556 | $16,020 | 129 | $117 | - | $176 | - | $232,781 1,190,811 kWh |
$20,760 1,556 kW-months/year |
$16,020 129 MMBtu |
$117 - $ |
$176 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: - Cost: - |
- | - | - | - | - | - | - | - | - | - | - - kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | LPG | Administrative Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | LPG | Administrative Changes | Ancillary Material Cost |