IAC logo
IAC Assessment: CI0045
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: CI0045
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of California, Irvine
Assessment Year 2025
Principal Product Shelf Liner, Grip
NAICS 322299 - All Other Converted Paper Product Manufacturing
SIC 2675 - Die-cut Paper And Board
Sales $10,000,000-$50,000,000
# of Employees 180
Plant Area (Sq.Ft.) 250,000
Annual Production 9,732,000 Units
Production Hrs. Annual 4,160
Location (State) CA
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $156,158 1,344,056 kWh $0.12
Electricity Demand $146,762 7,358 kW-months/year $19.95
Electricity Fees $59,448 - $ -
Natural Gas $40,344 3,806 MMBtu $10.60
Other Gas $10,145 1 MMBtu $10,145.00
TOTAL ENERGY COSTS $412,857
RECOMMENDED SAVINGS* $613,294 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* -
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Natural Gas Personnel Changes One-time Revenue or Avoided Cost Electricity Usage Electricity Demand Natural Gas Personnel Changes One-time Revenue or Avoided Cost
$ kWh $ kW-months/year $ MMBtu $ $ $ $
01: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY Savings:
$360,332
Cost:
$3,128,595
$274,212 2,359,829 $86,120 4,317 - - - - - - $274,212
2,359,829
kWh
$86,120
4,317
kW-months/year
-
-
MMBtu
-
-
$
-
-
$
02: 2.3141 USE BATTERY STORAGE FOR DEMAND CONTROL Savings:
$118,038
Cost:
$200,000
$118,038 1,015,820 - - - - - - - - $118,038
1,015,820
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
$
-
-
$
03: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$75,467
Cost:
$293,581
$46,246 397,986 $23,721 1,189 - - - - $5,500 - $46,246
397,986
kWh
$23,721
1,189
kW-months/year
-
-
MMBtu
-
-
$
$5,500
-
$
04: 2.7134 USE PHOTOCELL CONTROLS Savings:
$36,786
Cost:
$6,000
$15,181 130,647 $16,426 823 - - $208 - $4,971 - $15,181
130,647
kWh
$16,426
823
kW-months/year
-
-
MMBtu
$208
-
$
$4,971
-
$
05: 2.2511 INSULATE BARE EQUIPMENT Savings:
$13,658
Cost:
$2,310
- - - - $13,658 1,289 - - - - -
-
kWh
-
-
kW-months/year
$13,658
1,289
MMBtu
-
-
$
-
-
$
06: 2.4322 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES Savings:
$4,072
Cost:
$25,000
$4,072 35,041 - - - - - - - - $4,072
35,041
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
$
-
-
$
07: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT Savings:
$3,694
Cost:
$5,000
- - - - $3,694 349 - - - - -
-
kWh
-
-
kW-months/year
$3,694
349
MMBtu
-
-
$
-
-
$
08: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS Savings:
$1,247
Cost:
$910
$909 7,826 $338 17 - - - - - - $909
7,826
kWh
$338
17
kW-months/year
-
-
MMBtu
-
-
$
-
-
$
TOTAL RECOMMENDED Savings:
$613,294
Cost:
$3,661,396
$458,658 3,947,149 $126,605 6,346 $17,352 1,637 $208 - $10,471 - $458,658
3,947,149
kWh
$126,605
6,346
kW-months/year
$17,352
1,637
MMBtu
$208
-
$
$10,471
-
$
TOTAL IMPLEMENTED Savings:
-
Cost:
-
- - - - - - - - - - -
-
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
$
-
-
$
Savings
Cost
$ kWh $ kW-months/year $ MMBtu $ $ $ $
Electricity Usage Electricity Demand Natural Gas Personnel Changes One-time Revenue or Avoided Cost Electricity Usage Electricity Demand Natural Gas Personnel Changes One-time Revenue or Avoided Cost