Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of California, Irvine |
---|---|
Assessment Year | 2025 |
Principal Product | Shelf Liner, Grip |
NAICS | 322299 - All Other Converted Paper Product Manufacturing |
SIC | 2675 - Die-cut Paper And Board |
Sales | $10,000,000-$50,000,000 |
# of Employees | 180 |
Plant Area (Sq.Ft.) | 250,000 |
Annual Production | 9,732,000 Units |
Production Hrs. Annual | 4,160 |
Location (State) | CA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $156,158 | 1,344,056 | kWh | $0.12 |
Electricity Demand | $146,762 | 7,358 | kW-months/year | $19.95 |
Electricity Fees | $59,448 | - | $ | - |
Natural Gas | $40,344 | 3,806 | MMBtu | $10.60 |
Other Gas | $10,145 | 1 | MMBtu | $10,145.00 |
TOTAL ENERGY COSTS | $412,857 | |||
RECOMMENDED SAVINGS* | $613,294 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | - |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | One-time Revenue or Avoided Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY |
Savings: $360,332 Cost: $3,128,595 |
$274,212 | 2,359,829 | $86,120 | 4,317 | - | - | - | - | - | - |
$274,212 2,359,829 kWh |
$86,120 4,317 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.3141 USE BATTERY STORAGE FOR DEMAND CONTROL |
Savings: $118,038 Cost: $200,000 |
$118,038 | 1,015,820 | - | - | - | - | - | - | - | - |
$118,038 1,015,820 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $75,467 Cost: $293,581 |
$46,246 | 397,986 | $23,721 | 1,189 | - | - | - | - | $5,500 | - |
$46,246 397,986 kWh |
$23,721 1,189 kW-months/year |
- - MMBtu |
- - $ |
$5,500 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7134 USE PHOTOCELL CONTROLS |
Savings: $36,786 Cost: $6,000 |
$15,181 | 130,647 | $16,426 | 823 | - | - | $208 | - | $4,971 | - |
$15,181 130,647 kWh |
$16,426 823 kW-months/year |
- - MMBtu |
$208 - $ |
$4,971 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.2511 INSULATE BARE EQUIPMENT |
Savings: $13,658 Cost: $2,310 |
- | - | - | - | $13,658 | 1,289 | - | - | - | - |
- - kWh |
- - kW-months/year |
$13,658 1,289 MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4322 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES |
Savings: $4,072 Cost: $25,000 |
$4,072 | 35,041 | - | - | - | - | - | - | - | - |
$4,072 35,041 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT |
Savings: $3,694 Cost: $5,000 |
- | - | - | - | $3,694 | 349 | - | - | - | - |
- - kWh |
- - kW-months/year |
$3,694 349 MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $1,247 Cost: $910 |
$909 | 7,826 | $338 | 17 | - | - | - | - | - | - |
$909 7,826 kWh |
$338 17 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $613,294 Cost: $3,661,396 |
$458,658 | 3,947,149 | $126,605 | 6,346 | $17,352 | 1,637 | $208 | - | $10,471 | - | $458,658 3,947,149 kWh |
$126,605 6,346 kW-months/year |
$17,352 1,637 MMBtu |
$208 - $ |
$10,471 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: - Cost: - |
- | - | - | - | - | - | - | - | - | - | - - kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | One-time Revenue or Avoided Cost |