IAC Center Clemson University
Assessment Year 2019
Principal Product Liquid Flow Meters - Coriolis
NAICS 334519 - Other Measuring and Controlling Device Manufacturing
SIC 3824 - Fluid Meters And Counting Devices
Sales $14,000,000
# of Employees 65
Plant Area (Sq.Ft.) 127,755
Annual Production 4,500 Pieces
Production Hrs. Annual 2,250
Location (State) SC
Source Yearly Cost Usage
Electricity Usage $64,398 1,335,000
Electricity Demand $6,078 481
Electricity Fees $1,602 -
Natural Gas $12,030 1,760,100
TOTAL ENERGY COSTS $89,487
RECOMMENDED SAVINGS* $20,773 *Non-energy impacts
included in savings.
IMPLEMENTED SAVINGS* -
#|Description Status Electricity Usage Electricity Demand Electricity Usage Electricity Demand
$ kWh $ kW/month
01: 2.7111 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS Savings:
$11,750
Cost:
$6,882
$4,937 103 $6,813 539 $4,937
103
kWh
$6,813
539
kW/month
02: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$918
Cost:
$2,080
$369 7,693 $549 43 $369
7,693
kWh
$549
43
kW/month
03: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED Savings:
$5,441
Cost:
-
$2,188 45,581 $3,253 257 $2,188
45,581
kWh
$3,253
257
kW/month
04: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS Savings:
$2,525
Cost:
$1,600
$1,015 21,165 $1,510 120 $1,015
21,165
kWh
$1,510
120
kW/month
05: 2.7444 CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS Savings:
$139
Cost:
$900
$139 2,903 - - $139
2,903
kWh
-
-
kW/month
TOTAL RECOMMENDED Savings:
$20,773
Cost:
$11,462
$8,648 77,445 $12,125 959 $8,648
77,445
kWh
$12,125
959
kW/month
TOTAL IMPLEMENTED Savings:
-
Cost:
-
- - - - -
-
kWh
-
-
kW/month
$ kWh $ kW/month
Electricity Usage Electricity Demand Electricity Usage Electricity Demand
Back to Top