IAC logo
IAC Assessment: CL1915
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: CL1915
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Clemson University
Assessment Year 2019
Principal Product Clean Water
NAICS 221320 - Sewage Treatment Facilities
SIC 4952 - Sewerage Systems
Sales $10,000,000-$50,000,000
# of Employees 25
Plant Area (Sq.Ft.) 25,000
Annual Production 1,000,000 Thousand Gallons
Production Hrs. Annual 8,760
Location (State) SC
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $459,005 9,712,800 kWh $0.05
Electricity Demand $216,118 17,664 kW-months/year $12.23
Electricity Fees $1,020 - $ -
Natural Gas $22,681 1,983 MMBtu $11.44
TOTAL ENERGY COSTS $698,824
RECOMMENDED SAVINGS* $106,096 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $58,549
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Electricity Usage Electricity Demand
$ kWh $ kW-months/year
01: 2.3417 USE WASTE HEAT WITH A CLOSED-CYCLE GAS TURBINE-GENERATOR SET TO COGENERATE ELECTRICITY AND HEAT Savings:
$47,547
Cost:
$200,000
$35,111 742,304 $12,436 1,017 $35,111
742,304
kWh
$12,436
1,017
kW-months/year
02: 2.5122 REPLACE HIGH RESISTANCE DUCTS, PIPES, AND FITTINGS Savings:
$15,899
Cost:
$5,500
$11,741 248,229 $4,158 340 $11,741
248,229
kWh
$4,158
340
kW-months/year
03: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$40,751
Cost:
$41,281
$23,827 506,946 $16,924 1,383 $23,827
506,946
kWh
$16,924
1,383
kW-months/year
04: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED Savings:
$1,899
Cost:
-
$1,400 29,784 $499 41 $1,400
29,784
kWh
$499
41
kW-months/year
TOTAL RECOMMENDED Savings:
$106,096
Cost:
$246,781
$72,079 1,527,263 $34,017 2,781 $72,079
1,527,263
kWh
$34,017
2,781
kW-months/year
TOTAL IMPLEMENTED Savings:
$58,549
Cost:
$46,781
$36,968 784,959 $21,581 1,764 $36,968
784,959
kWh
$21,581
1,764
kW-months/year
Savings
Cost
$ kWh $ kW-months/year
Electricity Usage Electricity Demand Electricity Usage Electricity Demand