Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Clemson University |
---|---|
Assessment Year | 2020 |
Principal Product | Commercial faucets & fixtures |
NAICS | 332913 - Plumbing Fixture Fitting and Trim Manufacturing |
SIC | 3432 - Plumbing Fixture Fittings And Trim |
Sales | $100,000,000-$500,000,000 |
# of Employees | 320 |
Plant Area (Sq.Ft.) | 215,500 |
Annual Production | 1,000,000 Pieces |
Production Hrs. Annual | 4,700 |
Location (State) | SC |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $127,080 | 3,062,210 | kWh | $0.04 |
Electricity Demand | $85,949 | 8,924 | kW-months/year | $9.63 |
Electricity Fees | $14,668 | - | $ | - |
Natural Gas | $49,535 | 6,789 | MMBtu | $7.30 |
TOTAL ENERGY COSTS | $298,380 | |||
RECOMMENDED SAVINGS* | $19,358 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $18,145 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Usage | Electricity Demand | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $5,388 Cost: $1,300 |
$3,385 | 81,573 | $2,003 | 208 |
$3,385 81,573 kWh |
$2,003 208 kW-months/year |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $3,350 Cost: $1,650 |
$3,192 | 76,927 | $158 | 16 |
$3,192 76,927 kWh |
$158 16 kW-months/year |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $1,213 Cost: - |
$542 | 13,061 | $671 | 70 |
$542 13,061 kWh |
$671 70 kW-months/year |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4324 REPLACE HYDRAULIC / PNEUMATIC EQUIPMENT WITH ELECTRIC EQUIPMENT |
Savings: $9,407 Cost: $23,157 |
$5,845 | 140,851 | $3,562 | 370 |
$5,845 140,851 kWh |
$3,562 370 kW-months/year |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $19,358 Cost: $26,107 |
$12,964 | 312,412 | $6,394 | 664 | $12,964 312,412 kWh |
$6,394 664 kW-months/year |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $18,145 Cost: $26,107 |
$12,422 | 299,351 | $5,723 | 594 | $12,422 299,351 kWh |
$5,723 594 kW-months/year |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Usage | Electricity Demand |