Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Colorado State University
Assessment Year 1985
Principal Product PRINTED BUSINESS FORMS
NAICS n/a
SIC 2782 - Blankbooks And Looseleaf Binders
Sales $10,000,000-$50,000,000
# of Employees 105
Plant Area (Sq.Ft.) 0
Annual Production 10,800 Tons
Production Hrs. Annual 6,864
Location (State) CO
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $125,230 2,242,087 kWh $0.06
Natural Gas $15,423 3,157 MMBtu $4.89
TOTAL ENERGY COSTS $140,653
RECOMMENDED SAVINGS* $19,719 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $16,624
#|Description Savings
Cost
Status Electricity Usage Natural Gas Electricity Usage Natural Gas
$ kWh $ MMBtu
01: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$3,095
Cost:
$250
$3,095 55,393 - - $3,095
55,393
kWh
-
-
MMBtu
02: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS Savings:
$963
Cost:
$1,000
$963 17,292 - - $963
17,292
kWh
-
-
MMBtu
03: 2.7243 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS Savings:
$1,043
Cost:
$4,000
- - $1,043 213 -
-
kWh
$1,043
213
MMBtu
04: 2.7212 INSTALL OR UPGRADE INSULATION ON HVAC DISTRIBUTION SYSTEMS Savings:
$327
Cost:
$200
- - $327 67 -
-
kWh
$327
67
MMBtu
05: 2.6212 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME Savings:
$250
Cost:
$100
$250 4,396 - - $250
4,396
kWh
-
-
MMBtu
06: 2.3132 RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS Savings:
$888
Cost:
$200
$888 - - - $888
-
kWh
-
-
MMBtu
07: 2.7492 USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE Savings:
$298
Cost:
$600
- - $298 61 -
-
kWh
$298
61
MMBtu
08: 2.7211 CLEAN AND MAINTAIN REFRIGERANT CONDENSERS AND TOWERS Savings:
$231
Cost:
$300
$231 4,103 - - $231
4,103
kWh
-
-
MMBtu
09: 2.7261 INSTALL TIMERS AND/OR THERMOSTATS Savings:
$4,196
Cost:
$100
$4,196 75,029 - - $4,196
75,029
kWh
-
-
MMBtu
10: 2.7221 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA Savings:
$994
Cost:
$100
$994 17,878 - - $994
17,878
kWh
-
-
MMBtu
11: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$7,434
Cost:
$596
$7,434 133,060 - - $7,434
133,060
kWh
-
-
MMBtu
TOTAL RECOMMENDED Savings:
$19,719
Cost:
$7,446
$18,051 307,151 $1,668 341 $18,051
307,151
kWh
$1,668
341
MMBtu
TOTAL IMPLEMENTED Savings:
$16,624
Cost:
$6,046
$14,956 267,585 $1,668 341 $14,956
267,585
kWh
$1,668
341
MMBtu
Savings
Cost
$ kWh $ MMBtu
Electricity Usage Natural Gas Electricity Usage Natural Gas