Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Colorado State University
Assessment Year 1987
Principal Product PRESTRESSED CONCRETE
NAICS n/a
SIC 3272 - Concrete Products, Nec
Sales $10,000,000-$50,000,000
# of Employees 100
Plant Area (Sq.Ft.) 0
Annual Production 810 Thousand Feet
Production Hrs. Annual 6,240
Location (State) CO
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $86,843 1,346,131 kWh $0.06
Natural Gas $103,892 26,167 MMBtu $3.97
TOTAL ENERGY COSTS $190,735
RECOMMENDED SAVINGS* $28,558 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $24,341
#|Description Savings
Cost
Status Electricity Usage Natural Gas Electricity Usage Natural Gas
$ kWh $ MMBtu
01: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE Savings:
$9,969
Cost:
$200
- - $9,969 2,511 -
-
kWh
$9,969
2,511
MMBtu
02: 2.2135 REPAIR AND ELIMINATE STEAM LEAKS Savings:
$2,954
Cost:
$600
- - $2,954 744 -
-
kWh
$2,954
744
MMBtu
03: 2.7261 INSTALL TIMERS AND/OR THERMOSTATS Savings:
$7,174
Cost:
$1,000
- - $7,174 1,807 -
-
kWh
$7,174
1,807
MMBtu
04: 2.3191 USE DEMAND CONTROLLER OR LOAD SHEDDER Savings:
$2,574
Cost:
$2,000
$2,574 - - - $2,574
-
kWh
-
-
MMBtu
05: 2.4312 IMPROVE LUBRICATION PRACTICES Savings:
$265
Cost:
-
$265 4,103 - - $265
4,103
kWh
-
-
MMBtu
06: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE Savings:
$2,042
Cost:
-
$2,042 31,653 - - $2,042
31,653
kWh
-
-
MMBtu
07: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT Savings:
$421
Cost:
$500
- - $421 106 -
-
kWh
$421
106
MMBtu
08: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$1,040
Cost:
$200
$1,040 16,120 - - $1,040
16,120
kWh
-
-
MMBtu
09: 2.2492 USE "HEAT WHEEL" OR OTHER HEAT EXCHANGER TO CROSS-EXCHANGE BUILDING EXHAUST AIR WITH MAKE-UP AIR Savings:
$1,378
Cost:
$2,829
- - $1,378 347 -
-
kWh
$1,378
347
MMBtu
10: 2.2136 INSTALL / REPAIR INSULATION ON STEAM LINES Savings:
$155
Cost:
$347
- - $155 39 -
-
kWh
$155
39
MMBtu
11: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$586
Cost:
$366
$586 9,086 - - $586
9,086
kWh
-
-
MMBtu
TOTAL RECOMMENDED Savings:
$28,558
Cost:
$8,042
$6,507 60,962 $22,051 5,554 $6,507
60,962
kWh
$22,051
5,554
MMBtu
TOTAL IMPLEMENTED Savings:
$24,341
Cost:
$3,213
$3,668 56,859 $20,673 5,207 $3,668
56,859
kWh
$20,673
5,207
MMBtu
Savings
Cost
$ kWh $ MMBtu