IAC logo
IAC Assessment: CO0092
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: CO0092
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Colorado State University
Assessment Year 1987
Principal Product SPEED REDUCTION EQUIP
NAICS n/a
SIC 3566 - Speed Changers, Drives, And Gears
Sales $10,000,000-$50,000,000
# of Employees 200
Plant Area (Sq.Ft.) 0
Annual Production 70,000 Pieces
Production Hrs. Annual 7,488
Location (State) CO
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $183,761 3,670,868 kWh $0.05
Natural Gas $56,074 13,101 MMBtu $4.28
TOTAL ENERGY COSTS $239,835
RECOMMENDED SAVINGS* $22,886 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $18,144
#|Description Savings
Cost
Status Electricity Usage Natural Gas Electricity Usage Natural Gas
$ kWh $ MMBtu
01: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS Savings:
$1,461
Cost:
$500
$1,461 29,308 - - $1,461
29,308
kWh
-
-
MMBtu
02: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT Savings:
$2,213
Cost:
$3,000
- - $2,213 517 -
-
kWh
$2,213
517
MMBtu
03: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$3,081
Cost:
$250
$3,081 61,547 - - $3,081
61,547
kWh
-
-
MMBtu
04: 2.3132 RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS Savings:
$1,490
Cost:
$2,000
$1,490 - - - $1,490
-
kWh
-
-
MMBtu
05: 2.1221 REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES Savings:
$2,800
Cost:
$13,500
- - $2,800 654 -
-
kWh
$2,800
654
MMBtu
06: 2.7314 REDUCE VENTILATION AIR Savings:
$300
Cost:
$36
$107 2,052 $193 45 $107
2,052
kWh
$193
45
MMBtu
07: 2.2511 INSULATE BARE EQUIPMENT Savings:
$187
Cost:
$60
- - $187 44 -
-
kWh
$187
44
MMBtu
08: 2.7492 USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE Savings:
$2,609
Cost:
$10,000
- - $2,609 610 -
-
kWh
$2,609
610
MMBtu
09: 2.7492 USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE Savings:
$149
Cost:
$525
- - $149 35 -
-
kWh
$149
35
MMBtu
10: 2.7243 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS Savings:
$1,942
Cost:
$4,800
$(-307) (-6,155) $2,249 525 $(-307)
(-6,155)
kWh
$2,249
525
MMBtu
11: 2.7261 INSTALL TIMERS AND/OR THERMOSTATS Savings:
$2,841
Cost:
$474
$299 5,862 $2,542 594 $299
5,862
kWh
$2,542
594
MMBtu
12: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$3,813
Cost:
$2,762
$3,813 76,202 - - $3,813
76,202
kWh
-
-
MMBtu
TOTAL RECOMMENDED Savings:
$22,886
Cost:
$37,907
$9,944 168,816 $12,942 3,024 $9,944
168,816
kWh
$12,942
3,024
MMBtu
TOTAL IMPLEMENTED Savings:
$18,144
Cost:
$19,607
$10,251 174,971 $7,893 1,845 $10,251
174,971
kWh
$7,893
1,845
MMBtu
Savings
Cost
$ kWh $ MMBtu
Electricity Usage Natural Gas Electricity Usage Natural Gas