Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Colorado State University
Assessment Year 1991
Principal Product WIRE COATING
NAICS n/a
SIC 3643 - Current-carrying Wiring Devices
Sales $10,000,000-$50,000,000
# of Employees 90
Plant Area (Sq.Ft.) 0
Annual Production 5 Thousand Feet
Production Hrs. Annual 6,240
Location (State) NE
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $243,727 4,150,059 kWh $0.06
Natural Gas $14,774 3,520 MMBtu $4.20
TOTAL ENERGY COSTS $258,501
RECOMMENDED SAVINGS* $3,568 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* -
#|Description Savings
Cost
Status Electricity Usage Natural Gas Electricity Usage Natural Gas
$ kWh $ MMBtu
01: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS Savings:
$1,300
Cost:
$800
$1,300 22,860 - - $1,300
22,860
kWh
-
-
MMBtu
02: 2.8121 APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES Savings:
$760
Cost:
$250
- - $760 - -
-
kWh
$760
-
MMBtu
03: 2.7261 INSTALL TIMERS AND/OR THERMOSTATS Savings:
$470
Cost:
$500
$200 7,034 $270 64 $200
7,034
kWh
$270
64
MMBtu
04: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$353
Cost:
$367
$353 6,155 - - $353
6,155
kWh
-
-
MMBtu
05: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$210
Cost:
$770
$210 3,517 - - $210
3,517
kWh
-
-
MMBtu
06: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS Savings:
$475
Cost:
$1,060
$475 7,913 - - $475
7,913
kWh
-
-
MMBtu
TOTAL RECOMMENDED Savings:
$3,568
Cost:
$3,747
$2,538 47,479 $1,030 64 $2,538
47,479
kWh
$1,030
64
MMBtu
TOTAL IMPLEMENTED Savings:
-
Cost:
-
- - - - -
-
kWh
-
-
MMBtu
Savings
Cost
$ kWh $ MMBtu
Electricity Usage Natural Gas Electricity Usage Natural Gas