IAC logo
IAC Assessment: CO0208
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: CO0208
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Colorado State University
Assessment Year 1991
Principal Product RESISTORS
NAICS n/a
SIC 3676 - Electronic Resistors
Sales $10,000,000-$50,000,000
# of Employees 250
Plant Area (Sq.Ft.) 0
Annual Production 5,000,000 Pieces
Production Hrs. Annual 4,108
Location (State) CO
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $139,637 2,670,281 kWh $0.05
Natural Gas $7,113 1,513 MMBtu $4.70
TOTAL ENERGY COSTS $146,750
RECOMMENDED SAVINGS* $8,979 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $8,979
#|Description Savings
Cost
Status Electricity Usage Natural Gas Electricity Usage Natural Gas
$ kWh $ MMBtu
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$2,981
Cost:
$1,608
$2,981 57,151 - - $2,981
57,151
kWh
-
-
MMBtu
02: 2.7226 USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE Savings:
$2,800
Cost:
$10,000
$2,800 101,993 - - $2,800
101,993
kWh
-
-
MMBtu
03: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS Savings:
$300
Cost:
$892
$300 5,862 - - $300
5,862
kWh
-
-
MMBtu
04: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$458
Cost:
$1,300
$458 8,792 - - $458
8,792
kWh
-
-
MMBtu
05: 2.7133 USE SEPARATE SWITCHES ON PERIMETER LIGHTING WHICH MAY BE TURNED OFF WHEN NATURAL LIGHT IS AVAILABLE Savings:
$1,100
Cost:
$200
$1,100 21,102 - - $1,100
21,102
kWh
-
-
MMBtu
06: 2.7261 INSTALL TIMERS AND/OR THERMOSTATS Savings:
$800
Cost:
$1,500
$585 21,395 $215 46 $585
21,395
kWh
$215
46
MMBtu
07: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS Savings:
$540
Cost:
$500
$540 10,258 - - $540
10,258
kWh
-
-
MMBtu
TOTAL RECOMMENDED Savings:
$8,979
Cost:
$16,000
$8,764 226,553 $215 46 $8,764
226,553
kWh
$215
46
MMBtu
TOTAL IMPLEMENTED Savings:
$8,979
Cost:
$16,000
$8,764 226,553 $215 46 $8,764
226,553
kWh
$215
46
MMBtu
Savings
Cost
$ kWh $ MMBtu
Electricity Usage Natural Gas Electricity Usage Natural Gas