Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Colorado State University
Assessment Year 1992
Principal Product Injection Molded Plastic Products
NAICS n/a
SIC 3089 - Plastics Products, Nec
Sales $5,000,000-$10,000,000
# of Employees 250
Plant Area (Sq.Ft.) 134,000
Annual Production 4,400,000 Pounds
Production Hrs. Annual 7,488
Location (State) CO
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $356,460 7,355,803 kWh $0.05
Natural Gas $46,034 12,823 MMBtu $3.59
TOTAL ENERGY COSTS $402,494
RECOMMENDED SAVINGS* $47,180 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $47,180
#|Description Savings
Cost
Status Electricity Usage Natural Gas Administrative Changes Primary Product Electricity Usage Natural Gas Administrative Changes Primary Product
$ kWh $ MMBtu $ $ $ $
01: 2.6212 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME Savings:
$7,020
Cost:
$1,250
$7,020 136,577 - - - - - - $7,020
136,577
kWh
-
-
MMBtu
-
-
$
-
-
$
02: 2.2612 USE COOLING TOWER WATER INSTEAD OF REFRIGERATION Savings:
$2,990
Cost:
$1,800
$2,990 89,097 - - - - - - $2,990
89,097
kWh
-
-
MMBtu
-
-
$
-
-
$
03: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$3,480
Cost:
$2,560
$3,480 71,805 - - - - - - $3,480
71,805
kWh
-
-
MMBtu
-
-
$
-
-
$
04: 2.7111 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS Savings:
$1,610
Cost:
$40
$1,610 48,066 - - - - - - $1,610
48,066
kWh
-
-
MMBtu
-
-
$
-
-
$
05: 2.1123 INSTALL AUTOMATIC STACK DAMPER Savings:
$6,430
Cost:
$6,000
- - $6,430 1,791 - - - - -
-
kWh
$6,430
1,791
MMBtu
-
-
$
-
-
$
06: 2.7243 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS Savings:
$5,850
Cost:
$7,600
$(-130) (-2,638) $5,980 1,667 - - - - $(-130)
(-2,638)
kWh
$5,980
1,667
MMBtu
-
-
$
-
-
$
07: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS Savings:
$490
Cost:
$780
$490 9,965 - - - - - - $490
9,965
kWh
-
-
MMBtu
-
-
$
-
-
$
08: 2.7224 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS Savings:
$590
Cost:
$1,350
$400 12,016 $190 54 - - - - $400
12,016
kWh
$190
54
MMBtu
-
-
$
-
-
$
09: 2.4224 UPGRADE CONTROLS ON COMPRESSORS Savings:
$5,970
Cost:
$12,000
$350 7,034 - - - - $5,620 - $350
7,034
kWh
-
-
MMBtu
-
-
$
$5,620
-
$
10: 2.7442 KEEP DOORS AND WINDOWS SHUT WHEN NOT ON USE Savings:
$230
Cost:
$530
- - $230 64 - - - - -
-
kWh
$230
64
MMBtu
-
-
$
-
-
$
11: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS Savings:
$3,470
Cost:
$6,280
$3,470 71,512 - - - - - - $3,470
71,512
kWh
-
-
MMBtu
-
-
$
-
-
$
12: 2.8114 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE Savings:
$9,050
Cost:
$30,250
- - - - $9,050 - - - -
-
kWh
-
-
MMBtu
$9,050
-
$
-
-
$
TOTAL RECOMMENDED Savings:
$47,180
Cost:
$70,440
$19,680 443,434 $12,830 3,576 $9,050 - $5,620 - $19,680
443,434
kWh
$12,830
3,576
MMBtu
$9,050
-
$
$5,620
-
$
TOTAL IMPLEMENTED Savings:
$47,180
Cost:
$70,440
$19,680 443,434 $12,830 3,576 $9,050 - $5,620 - $19,680
443,434
kWh
$12,830
3,576
MMBtu
$9,050
-
$
$5,620
-
$
Savings
Cost
$ kWh $ MMBtu $ $ $ $
Electricity Usage Natural Gas Administrative Changes Primary Product Electricity Usage Natural Gas Administrative Changes Primary Product