IAC logo
IAC Assessment: CO0310
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: CO0310
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Colorado State University
Assessment Year 1994
Principal Product quartz crystals
NAICS n/a
SIC 3679 - Electronic Components, Nec
Sales $1,000,000-$5,000,000
# of Employees 125
Plant Area (Sq.Ft.) 22,000
Annual Production 200,000 Pieces
Production Hrs. Annual 8,640
Location (State) CO
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $55,850 1,083,822 kWh $0.05
Natural Gas $5,060 1,256 MMBtu $4.03
TOTAL ENERGY COSTS $60,910
RECOMMENDED SAVINGS* $21,540 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $6,610
#|Description Savings
Cost
Status Electricity Usage Natural Gas Water Disposal Other Liquid (non-haz) Other Liquid (haz) Electricity Usage Natural Gas Water Disposal Other Liquid (non-haz) Other Liquid (haz)
$ kWh $ MMBtu $ Tgal $ gal $ gal
01: 3.5314 USE IN-PROCESS RECYCLING WHENEVER POSSIBLE Savings:
$7,150
Cost:
-
- - - - - - $7,150 9,990 - - -
-
kWh
-
-
MMBtu
-
-
Tgal
$7,150
9,990
gal
-
-
gal
02: 2.2614 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING Savings:
$4,900
Cost:
$3,810
$(-190) (-3,517) - - $5,090 13,135,000 - - - - $(-190)
(-3,517)
kWh
-
-
MMBtu
$5,090
13,135,000
Tgal
-
-
gal
-
-
gal
03: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$3,070
Cost:
$6,820
$3,070 59,496 - - - - - - - - $3,070
59,496
kWh
-
-
MMBtu
-
-
Tgal
-
-
gal
-
-
gal
04: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$2,880
Cost:
$1,720
$2,880 55,979 - - - - - - - - $2,880
55,979
kWh
-
-
MMBtu
-
-
Tgal
-
-
gal
-
-
gal
05: 3.5314 USE IN-PROCESS RECYCLING WHENEVER POSSIBLE Savings:
$1,840
Cost:
-
- - - - - - - - $1,840 2,200 -
-
kWh
-
-
MMBtu
-
-
Tgal
-
-
gal
$1,840
2,200
gal
06: 2.7314 REDUCE VENTILATION AIR Savings:
$850
Cost:
$550
$470 13,775 $380 96 - - - - - - $470
13,775
kWh
$380
96
MMBtu
-
-
Tgal
-
-
gal
-
-
gal
07: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS Savings:
$440
Cost:
$730
$440 8,499 - - - - - - - - $440
8,499
kWh
-
-
MMBtu
-
-
Tgal
-
-
gal
-
-
gal
08: 2.7211 CLEAN AND MAINTAIN REFRIGERANT CONDENSERS AND TOWERS Savings:
$410
Cost:
$90
$410 7,913 - - - - - - - - $410
7,913
kWh
-
-
MMBtu
-
-
Tgal
-
-
gal
-
-
gal
TOTAL RECOMMENDED Savings:
$21,540
Cost:
$13,720
$7,080 142,145 $380 96 $5,090 13,135,000 $7,150 9,990 $1,840 2,200 $7,080
142,145
kWh
$380
96
MMBtu
$5,090
13,135,000
Tgal
$7,150
9,990
gal
$1,840
2,200
gal
TOTAL IMPLEMENTED Savings:
$6,610
Cost:
$8,190
$4,390 89,683 $380 96 - - - - $1,840 2,200 $4,390
89,683
kWh
$380
96
MMBtu
-
-
Tgal
-
-
gal
$1,840
2,200
gal
Savings
Cost
$ kWh $ MMBtu $ Tgal $ gal $ gal
Electricity Usage Natural Gas Water Disposal Other Liquid (non-haz) Other Liquid (haz) Electricity Usage Natural Gas Water Disposal Other Liquid (non-haz) Other Liquid (haz)