Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Colorado State University |
---|---|
Assessment Year | 1994 |
Principal Product | quartz crystals |
NAICS | n/a |
SIC | 3679 - Electronic Components, Nec |
Sales | $1,000,000-$5,000,000 |
# of Employees | 125 |
Plant Area (Sq.Ft.) | 22,000 |
Annual Production | 200,000 Pieces |
Production Hrs. Annual | 8,640 |
Location (State) | CO |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $55,850 | 1,083,822 | kWh | $0.05 |
Natural Gas | $5,060 | 1,256 | MMBtu | $4.03 |
TOTAL ENERGY COSTS | $60,910 | |||
RECOMMENDED SAVINGS* | $21,540 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $6,610 |
#|Description |
Savings Cost |
Status | Electricity Usage | Natural Gas | Water Disposal | Other Liquid (non-haz) | Other Liquid (haz) | Electricity Usage | Natural Gas | Water Disposal | Other Liquid (non-haz) | Other Liquid (haz) | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | MMBtu | $ | Tgal | $ | gal | $ | gal | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 3.5314 USE IN-PROCESS RECYCLING WHENEVER POSSIBLE |
Savings: $7,150 Cost: - |
- | - | - | - | - | - | $7,150 | 9,990 | - | - |
- - kWh |
- - MMBtu |
- - Tgal |
$7,150 9,990 gal |
- - gal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.2614 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING |
Savings: $4,900 Cost: $3,810 |
$(-190) | (-3,517) | - | - | $5,090 | 13,135,000 | - | - | - | - |
$(-190) (-3,517) kWh |
- - MMBtu |
$5,090 13,135,000 Tgal |
- - gal |
- - gal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $3,070 Cost: $6,820 |
$3,070 | 59,496 | - | - | - | - | - | - | - | - |
$3,070 59,496 kWh |
- - MMBtu |
- - Tgal |
- - gal |
- - gal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $2,880 Cost: $1,720 |
$2,880 | 55,979 | - | - | - | - | - | - | - | - |
$2,880 55,979 kWh |
- - MMBtu |
- - Tgal |
- - gal |
- - gal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 3.5314 USE IN-PROCESS RECYCLING WHENEVER POSSIBLE |
Savings: $1,840 Cost: - |
- | - | - | - | - | - | - | - | $1,840 | 2,200 |
- - kWh |
- - MMBtu |
- - Tgal |
- - gal |
$1,840 2,200 gal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7314 REDUCE VENTILATION AIR |
Savings: $850 Cost: $550 |
$470 | 13,775 | $380 | 96 | - | - | - | - | - | - |
$470 13,775 kWh |
$380 96 MMBtu |
- - Tgal |
- - gal |
- - gal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $440 Cost: $730 |
$440 | 8,499 | - | - | - | - | - | - | - | - |
$440 8,499 kWh |
- - MMBtu |
- - Tgal |
- - gal |
- - gal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.7211 CLEAN AND MAINTAIN REFRIGERANT CONDENSERS AND TOWERS |
Savings: $410 Cost: $90 |
$410 | 7,913 | - | - | - | - | - | - | - | - |
$410 7,913 kWh |
- - MMBtu |
- - Tgal |
- - gal |
- - gal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $21,540 Cost: $13,720 |
$7,080 | 142,145 | $380 | 96 | $5,090 | 13,135,000 | $7,150 | 9,990 | $1,840 | 2,200 | $7,080 142,145 kWh |
$380 96 MMBtu |
$5,090 13,135,000 Tgal |
$7,150 9,990 gal |
$1,840 2,200 gal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $6,610 Cost: $8,190 |
$4,390 | 89,683 | $380 | 96 | - | - | - | - | $1,840 | 2,200 | $4,390 89,683 kWh |
$380 96 MMBtu |
- - Tgal |
- - gal |
$1,840 2,200 gal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | MMBtu | $ | Tgal | $ | gal | $ | gal | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Natural Gas | Water Disposal | Other Liquid (non-haz) | Other Liquid (haz) | Electricity Usage | Natural Gas | Water Disposal | Other Liquid (non-haz) | Other Liquid (haz) |