Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Colorado State University |
---|---|
Assessment Year | 1996 |
Principal Product | unfinished center pivot irrigation systems |
NAICS | n/a |
SIC | 3523 - Farm Machinery And Equipment |
Sales | $50,000,000-$100,000,000 |
# of Employees | 250 |
Plant Area (Sq.Ft.) | 164,500 |
Annual Production | 10,000 Tons |
Production Hrs. Annual | 7,488 |
Location (State) | NE |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $163,977 | 7,674,092 | kWh | $0.02 |
Electricity Demand | $133,316 | 17,816 | kW-months/year | $7.48 |
Electricity Fees | $363 | - | $ | - |
Natural Gas | $131,129 | 49,826 | MMBtu | $2.63 |
TOTAL ENERGY COSTS | $429,815 | |||
RECOMMENDED SAVINGS* | $25,368 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $23,305 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Other Liquid (haz) | Ancillary Material Cost | Electricity Usage | Electricity Demand | Natural Gas | Other Liquid (haz) | Ancillary Material Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | gal | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7231 USE RADIANT HEATER FOR SPOT HEATING |
Savings: $13,520 Cost: $6,200 |
$18,200 | 469,226 | - | - | $(-4,680) | (-1,779) | - | - | - | - |
$18,200 469,226 kWh |
- - kW-months/year |
$(-4,680) (-1,779) MMBtu |
- - gal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $4,200 Cost: $160 |
$2,690 | 125,733 | $1,510 | 201 | - | - | - | - | - | - |
$2,690 125,733 kWh |
$1,510 201 kW-months/year |
- - MMBtu |
- - gal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $2,063 Cost: $4,806 |
$1,150 | 53,634 | $913 | 122 | - | - | - | - | - | - |
$1,150 53,634 kWh |
$913 122 kW-months/year |
- - MMBtu |
- - gal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $2,640 Cost: $1,870 |
$1,690 | 79,132 | $950 | 127 | - | - | - | - | - | - |
$1,690 79,132 kWh |
$950 127 kW-months/year |
- - MMBtu |
- - gal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $1,110 Cost: $40 |
$710 | 33,118 | $400 | 53 | - | - | - | - | - | - |
$710 33,118 kWh |
$400 53 kW-months/year |
- - MMBtu |
- - gal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $1,030 Cost: $1,080 |
$700 | 32,825 | $330 | 45 | - | - | - | - | - | - |
$700 32,825 kWh |
$330 45 kW-months/year |
- - MMBtu |
- - gal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $155 Cost: $187 |
$105 | 4,982 | $50 | 7 | - | - | - | - | - | - |
$105 4,982 kWh |
$50 7 kW-months/year |
- - MMBtu |
- - gal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 3.8132 USE LESS TOXIC AND VOLATILE SOLVENT SUBSTITUTES |
Savings: $650 Cost: $1,580 |
- | - | - | - | - | - | $1,010 | 120 | $(-360) | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$1,010 120 gal |
$(-360) - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $25,368 Cost: $15,923 |
$25,245 | 798,650 | $4,153 | 555 | $(-4,680) | (-1,779) | $1,010 | 120 | $(-360) | - | $25,245 798,650 kWh |
$4,153 555 kW-months/year |
$(-4,680) (-1,779) MMBtu |
$1,010 120 gal |
$(-360) - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $23,305 Cost: $11,117 |
$24,095 | 745,016 | $3,240 | 433 | $(-4,680) | (-1,779) | $1,010 | 120 | $(-360) | - | $24,095 745,016 kWh |
$3,240 433 kW-months/year |
$(-4,680) (-1,779) MMBtu |
$1,010 120 gal |
$(-360) - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | gal | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Other Liquid (haz) | Ancillary Material Cost | Electricity Usage | Electricity Demand | Natural Gas | Other Liquid (haz) | Ancillary Material Cost |