Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Colorado State University |
---|---|
Assessment Year | 1997 |
Principal Product | commercial printing |
NAICS | n/a |
SIC | 2752 - Commercial Printing, Lithographic |
Sales | $10,000,000-$50,000,000 |
# of Employees | 130 |
Plant Area (Sq.Ft.) | 80,000 |
Annual Production | 2,500,000 Pieces |
Production Hrs. Annual | 4,160 |
Location (State) | CO |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $32,111 | 1,428,488 | kWh | $0.02 |
Electricity Demand | $63,384 | 4,752 | kW-months/year | $13.34 |
Electricity Fees | $153 | - | $ | - |
Natural Gas | $5,858 | 1,583 | MMBtu | $3.70 |
TOTAL ENERGY COSTS | $107,216 | |||
RECOMMENDED SAVINGS* | $14,251 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $11,031 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Other Liquid (non-haz) | Other Liquid (haz) | Personnel Changes | Ancillary Material Cost | Increase in Production | Electricity Usage | Electricity Demand | Other Liquid (non-haz) | Other Liquid (haz) | Personnel Changes | Ancillary Material Cost | Increase in Production | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | gal | $ | gal | $ | $ | $ | $ | $ | % | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $1,461 Cost: $782 |
$434 | 24,326 | $1,027 | 72 | - | - | - | - | - | - | - | - | - | - |
$434 24,326 kWh |
$1,027 72 kW-months/year |
- - gal |
- - gal |
- - $ |
- - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $140 Cost: $202 |
$43 | 2,345 | $97 | 7 | - | - | - | - | - | - | - | - | - | - |
$43 2,345 kWh |
$97 7 kW-months/year |
- - gal |
- - gal |
- - $ |
- - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $370 Cost: $700 |
$130 | 7,327 | $240 | 17 | - | - | - | - | - | - | - | - | - | - |
$130 7,327 kWh |
$240 17 kW-months/year |
- - gal |
- - gal |
- - $ |
- - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $310 Cost: $730 |
$90 | 5,275 | $220 | 15 | - | - | - | - | - | - | - | - | - | - |
$90 5,275 kWh |
$220 15 kW-months/year |
- - gal |
- - gal |
- - $ |
- - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 3.8142 DISTILL CONTAMINATED SOLVENTS FOR REUSE |
Savings: $3,220 Cost: $3,600 |
$(-10) | (-586) | - | - | - | - | $570 | 350 | $(-440) | - | $3,100 | - | - | - |
$(-10) (-586) kWh |
- - kW-months/year |
- - gal |
$570 350 gal |
$(-440) - $ |
$3,100 - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 3.5121 RECYCLE WASTE INK AND CLEANUP SOLVENT |
Savings: $1,640 Cost: $1,640 |
- | - | - | - | $(-4,800) | 715 | - | - | - | - | $6,440 | - | - | - |
- - kWh |
- - kW-months/year |
$(-4,800) 715 gal |
- - gal |
- - $ |
$6,440 - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 4.653 MAINTAIN/ENLARGE A STOCK OF SPARE PARTS |
Savings: $7,110 Cost: $340 |
- | - | - | - | - | - | - | - | - | - | - | - | $7,110 | - |
- - kWh |
- - kW-months/year |
- - gal |
- - gal |
- - $ |
- - $ |
$7,110 - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $14,251 Cost: $7,994 |
$687 | 38,687 | $1,584 | 111 | $(-4,800) | 715 | $570 | 350 | $(-440) | - | $9,540 | - | $7,110 | - | $687 38,687 kWh |
$1,584 111 kW-months/year |
$(-4,800) 715 gal |
$570 350 gal |
$(-440) - $ |
$9,540 - $ |
$7,110 - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $11,031 Cost: $4,394 |
$697 | 39,273 | $1,584 | 111 | $(-4,800) | 715 | - | - | - | - | $6,440 | - | $7,110 | - | $697 39,273 kWh |
$1,584 111 kW-months/year |
$(-4,800) 715 gal |
- - gal |
- - $ |
$6,440 - $ |
$7,110 - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | gal | $ | gal | $ | $ | $ | $ | $ | % | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Other Liquid (non-haz) | Other Liquid (haz) | Personnel Changes | Ancillary Material Cost | Increase in Production | Electricity Usage | Electricity Demand | Other Liquid (non-haz) | Other Liquid (haz) | Personnel Changes | Ancillary Material Cost | Increase in Production |