Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Colorado State University |
---|---|
Assessment Year | 1999 |
Principal Product | corrugated containers |
NAICS | n/a |
SIC | 2653 - Corrugated And Solid Fiber Boxes |
Sales | $10,000,000-$50,000,000 |
# of Employees | 60 |
Plant Area (Sq.Ft.) | 121,000 |
Annual Production | 120,000,000 Thousand Feet |
Production Hrs. Annual | 4,420 |
Location (State) | CO |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $14,501 | 694,021 | kWh | $0.02 |
Electricity Demand | $47,672 | 3,460 | kW-months/year | $13.78 |
Electricity Fees | $516 | - | $ | - |
Natural Gas | $10,288 | 2,256 | MMBtu | $4.56 |
TOTAL ENERGY COSTS | $73,479 | |||
RECOMMENDED SAVINGS* | $203,110 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | - |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Ancillary Material Cost | Primary Product | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Ancillary Material Cost | Primary Product | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.3131 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS |
Savings: $4,820 Cost: $4,000 |
- | - | $4,820 | 348 | - | - | - | - | - | - | - | - |
- - kWh |
$4,820 348 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7447 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS |
Savings: $830 Cost: $1,080 |
- | - | - | - | $830 | 187 | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$830 187 MMBtu |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $430 Cost: $30 |
$430 | 6,155 | - | - | - | - | - | - | - | - | - | - |
$430 6,155 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7224 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS |
Savings: $380 Cost: $150 |
$80 | 4,103 | - | - | $300 | 68 | - | - | - | - | - | - |
$80 4,103 kWh |
- - kW-months/year |
$300 68 MMBtu |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $330 Cost: $210 |
$1,110 | 42,790 | - | - | - | - | $(-780) | - | - | - | - | - |
$1,110 42,790 kWh |
- - kW-months/year |
- - MMBtu |
$(-780) - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $20 Cost: - |
$100 | 5,569 | $200 | 15 | - | - | $(-40) | - | $(-240) | - | - | - |
$100 5,569 kWh |
$200 15 kW-months/year |
- - MMBtu |
$(-40) - $ |
$(-240) - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 4.111 ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK |
Savings: $160,300 Cost: $489,000 |
- | - | - | - | - | - | - | - | - | - | $160,300 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
$160,300 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 4.625 DEVELOP STANDARD OPERATING PROCEDURES |
Savings: $36,000 Cost: - |
- | - | - | - | - | - | - | - | - | - | $36,000 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
$36,000 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $203,110 Cost: $494,470 |
$1,720 | 58,617 | $5,020 | 363 | $1,130 | 255 | $(-820) | - | $(-240) | - | $196,300 | - | $1,720 58,617 kWh |
$5,020 363 kW-months/year |
$1,130 255 MMBtu |
$(-820) - $ |
$(-240) - $ |
$196,300 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: - Cost: - |
- | - | - | - | - | - | - | - | - | - | - | - | - - kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Ancillary Material Cost | Primary Product | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Ancillary Material Cost | Primary Product |