Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Colorado State University |
---|---|
Assessment Year | 2000 |
Principal Product | hydraulic fluid control valves |
NAICS | n/a |
SIC | 3492 - Fluid Power Valves & Hose Fittings |
Sales | $1,000,000-$5,000,000 |
# of Employees | 140 |
Plant Area (Sq.Ft.) | 62,500 |
Annual Production | 10,000 Pieces |
Production Hrs. Annual | 4,108 |
Location (State) | CO |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $61,067 | 2,084,701 | kWh | $0.03 |
Electricity Demand | $65,793 | 5,590 | kW-months/year | $11.77 |
Electricity Fees | $3,137 | - | $ | - |
Natural Gas | $27,773 | 4,343 | MMBtu | $6.39 |
TOTAL ENERGY COSTS | $158,870 | |||
RECOMMENDED SAVINGS* | $16,340 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $13,120 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Other Liquid (non-haz) | Solid Waste (haz) | Personnel Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Other Liquid (non-haz) | Solid Waste (haz) | Personnel Changes | Ancillary Material Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | gal | $ | lb | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.3131 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS |
Savings: $6,380 Cost: $7,500 |
- | - | $6,380 | 381 | - | - | - | - | - | - | - | - |
- - kWh |
$6,380 381 kW-months/year |
- - gal |
- - lb |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $1,340 Cost: $2,850 |
$570 | 24,033 | $770 | 51 | - | - | - | - | - | - | - | - |
$570 24,033 kWh |
$770 51 kW-months/year |
- - gal |
- - lb |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $660 Cost: - |
$380 | 17,878 | $1,120 | 72 | - | - | - | - | $(-240) | - | $(-600) | - |
$380 17,878 kWh |
$1,120 72 kW-months/year |
- - gal |
- - lb |
$(-240) - $ |
$(-600) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7124 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED |
Savings: $660 Cost: $1,000 |
$570 | 33,411 | - | - | - | - | - | - | - | - | $90 | - |
$570 33,411 kWh |
- - kW-months/year |
- - gal |
- - lb |
- - $ |
$90 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 3.3122 USE FILTRATION, CENTRIFUGING TO REMOVE CONTAMINANTS |
Savings: $1,880 Cost: - |
- | - | - | - | $50 | 1,200 | - | - | $360 | - | $1,470 | - |
- - kWh |
- - kW-months/year |
$50 1,200 gal |
- - lb |
$360 - $ |
$1,470 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 3.6192 USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL |
Savings: $320 Cost: - |
- | - | - | - | - | - | $360 | 125 | - | - | $(-40) | - |
- - kWh |
- - kW-months/year |
- - gal |
$360 125 lb |
- - $ |
$(-40) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 4.621 USE FIXTURES TO REDUCE MACHINE CHANGEOUT TIMES |
Savings: $5,100 Cost: $1,510 |
- | - | - | - | - | - | - | - | $5,100 | - | - | - |
- - kWh |
- - kW-months/year |
- - gal |
- - lb |
$5,100 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $16,340 Cost: $12,860 |
$1,520 | 75,322 | $8,270 | 504 | $50 | 1,200 | $360 | 125 | $5,220 | - | $920 | - | $1,520 75,322 kWh |
$8,270 504 kW-months/year |
$50 1,200 gal |
$360 125 lb |
$5,220 - $ |
$920 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $13,120 Cost: $10,010 |
$950 | 51,289 | $7,500 | 453 | - | - | $360 | 125 | $4,860 | - | $(-550) | - | $950 51,289 kWh |
$7,500 453 kW-months/year |
- - gal |
$360 125 lb |
$4,860 - $ |
$(-550) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | gal | $ | lb | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Other Liquid (non-haz) | Solid Waste (haz) | Personnel Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Other Liquid (non-haz) | Solid Waste (haz) | Personnel Changes | Ancillary Material Cost |