Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Colorado State University |
---|---|
Assessment Year | 2000 |
Principal Product | newspapers |
NAICS | n/a |
SIC | 2711 - Newspapers |
Sales | $5,000,000-$10,000,000 |
# of Employees | 113 |
Plant Area (Sq.Ft.) | 40,000 |
Annual Production | 135 Tons |
Production Hrs. Annual | 1,300 |
Location (State) | WY |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $37,879 | 1,523,447 | kWh | $0.02 |
Electricity Demand | $36,117 | 3,803 | kW-months/year | $9.50 |
Electricity Fees | $146 | - | $ | - |
Natural Gas | $9,011 | 2,352 | MMBtu | $3.83 |
TOTAL ENERGY COSTS | $90,600 | |||
RECOMMENDED SAVINGS* | $8,350 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $2,180 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Solid Waste (haz) | Ancillary Material Cost | Electricity Usage | Electricity Demand | Natural Gas | Solid Waste (haz) | Ancillary Material Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | lb | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.3191 USE DEMAND CONTROLLER OR LOAD SHEDDER |
Savings: $3,730 Cost: $2,000 |
- | - | $3,730 | 360 | - | - | - | - | - | - |
- - kWh |
$3,730 360 kW-months/year |
- - MMBtu |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT |
Savings: $1,280 Cost: $2,250 |
- | - | - | - | $1,280 | 323 | - | - | - | - |
- - kWh |
- - kW-months/year |
$1,280 323 MMBtu |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $1,840 Cost: - |
$570 | 25,205 | $630 | 60 | - | - | - | - | $640 | - |
$570 25,205 kWh |
$630 60 kW-months/year |
- - MMBtu |
- - lb |
$640 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $340 Cost: $370 |
$240 | 10,551 | $100 | 10 | - | - | - | - | - | - |
$240 10,551 kWh |
$100 10 kW-months/year |
- - MMBtu |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7491 INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS |
Savings: $320 Cost: $1,040 |
- | - | - | - | $320 | 810 | - | - | - | - |
- - kWh |
- - kW-months/year |
$320 810 MMBtu |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $310 Cost: $1,070 |
- | - | $120 | 12 | $190 | 29 | - | - | - | - |
- - kWh |
$120 12 kW-months/year |
$190 29 MMBtu |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 3.6192 USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL |
Savings: $530 Cost: - |
- | - | - | - | - | - | $550 | 194 | $(-20) | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$550 194 lb |
$(-20) - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $8,350 Cost: $6,730 |
$810 | 35,756 | $4,580 | 442 | $1,790 | 1,162 | $550 | 194 | $620 | - | $810 35,756 kWh |
$4,580 442 kW-months/year |
$1,790 1,162 MMBtu |
$550 194 lb |
$620 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $2,180 Cost: $370 |
$810 | 35,756 | $730 | 70 | - | - | - | - | $640 | - | $810 35,756 kWh |
$730 70 kW-months/year |
- - MMBtu |
- - lb |
$640 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | lb | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Solid Waste (haz) | Ancillary Material Cost | Electricity Usage | Electricity Demand | Natural Gas | Solid Waste (haz) | Ancillary Material Cost |