Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Colorado State University |
---|---|
Assessment Year | 2000 |
Principal Product | concrete pipe and ready mix concrete |
NAICS | n/a |
SIC | 3272 - Concrete Products, Nec |
Sales | $10,000,000-$50,000,000 |
# of Employees | 70 |
Plant Area (Sq.Ft.) | 41,848 |
Annual Production | 23,763 Tons |
Production Hrs. Annual | 2,772 |
Location (State) | CO |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $11,416 | 634,818 | kWh | $0.02 |
Electricity Demand | $57,409 | 4,131 | kW-months/year | $13.90 |
Electricity Fees | $834 | - | $ | - |
Natural Gas | $12,455 | 2,522 | MMBtu | $4.94 |
TOTAL ENERGY COSTS | $89,767 | |||
RECOMMENDED SAVINGS* | $13,170 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $4,100 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Solid Waste (non-haz) | Personnel Changes | Administrative Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Natural Gas | Solid Waste (non-haz) | Personnel Changes | Administrative Changes | Ancillary Material Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | lb | $ | $ | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.3191 USE DEMAND CONTROLLER OR LOAD SHEDDER |
Savings: $2,490 Cost: $5,000 |
- | - | $2,490 | 180 | - | - | - | - | - | - | - | - | - | - |
- - kWh |
$2,490 180 kW-months/year |
- - MMBtu |
- - lb |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7121 UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT |
Savings: $1,100 Cost: $1,000 |
$230 | 12,603 | $1,370 | 98 | - | - | - | - | - | - | $(-500) | - | - | - |
$230 12,603 kWh |
$1,370 98 kW-months/year |
- - MMBtu |
- - lb |
- - $ |
$(-500) - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.2511 INSULATE BARE EQUIPMENT |
Savings: $790 Cost: $180 |
- | - | - | - | $790 | 163 | - | - | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$790 163 MMBtu |
- - lb |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7224 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS |
Savings: $760 Cost: $1,490 |
- | - | - | - | $760 | 157 | - | - | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$760 157 MMBtu |
- - lb |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE |
Savings: $520 Cost: - |
- | - | - | - | $520 | 96 | - | - | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$520 96 MMBtu |
- - lb |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $30 Cost: - |
$30 | 1,758 | $110 | 8 | - | - | - | - | $(-110) | - | - | - | - | - |
$30 1,758 kWh |
$110 8 kW-months/year |
- - MMBtu |
- - lb |
$(-110) - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 3.1175 USE A DIFFERENT OR RECYCLED RAW MATERIAL |
Savings: $4,200 Cost: - |
- | - | - | - | - | - | - | - | - | - | - | - | $4,200 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - lb |
- - $ |
- - $ |
$4,200 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 3.5315 LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER |
Savings: $550 Cost: - |
- | - | - | - | - | - | $550 | - | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$550 - lb |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.8121 APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES |
Savings: $2,730 Cost: $250 |
- | - | - | - | - | - | - | - | - | - | $2,730 | - | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - lb |
- - $ |
$2,730 - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $13,170 Cost: $7,920 |
$260 | 14,361 | $3,970 | 286 | $2,070 | 416 | $550 | - | $(-110) | - | $2,230 | - | $4,200 | - | $260 14,361 kWh |
$3,970 286 kW-months/year |
$2,070 416 MMBtu |
$550 - lb |
$(-110) - $ |
$2,230 - $ |
$4,200 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $4,100 Cost: $430 |
$30 | 1,758 | $110 | 8 | $790 | 163 | $550 | - | $(-110) | - | $2,730 | - | - | - | $30 1,758 kWh |
$110 8 kW-months/year |
$790 163 MMBtu |
$550 - lb |
$(-110) - $ |
$2,730 - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | lb | $ | $ | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Solid Waste (non-haz) | Personnel Changes | Administrative Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Natural Gas | Solid Waste (non-haz) | Personnel Changes | Administrative Changes | Ancillary Material Cost |