Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Colorado State University |
---|---|
Assessment Year | 2000 |
Principal Product | finished household furniture |
NAICS | n/a |
SIC | 2511 - Wood Household Furniture |
Sales | $5,000,000-$10,000,000 |
# of Employees | 75 |
Plant Area (Sq.Ft.) | 31,000 |
Annual Production | 10,000 Pieces |
Production Hrs. Annual | 4,290 |
Location (State) | CO |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $14,850 | 995,604 | kWh | $0.01 |
Electricity Demand | $34,811 | 3,274 | kW-months/year | $10.63 |
Natural Gas | $14,689 | 3,324 | MMBtu | $4.42 |
TOTAL ENERGY COSTS | $74,552 | |||
RECOMMENDED SAVINGS* | $44,390 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $41,300 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Administrative Changes | Ancillary Material Cost | Primary Product | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Administrative Changes | Ancillary Material Cost | Primary Product | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7491 INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS |
Savings: $4,280 Cost: $12,550 |
- | - | - | - | $4,280 | 954 | - | - | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$4,280 954 MMBtu |
- - $ |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.3191 USE DEMAND CONTROLLER OR LOAD SHEDDER |
Savings: $2,960 Cost: $200 |
- | - | $3,440 | 324 | - | - | - | - | $(-480) | - | - | - | - | - |
- - kWh |
$3,440 324 kW-months/year |
- - MMBtu |
- - $ |
$(-480) - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7442 KEEP DOORS AND WINDOWS SHUT WHEN NOT ON USE |
Savings: $1,040 Cost: $1,000 |
- | - | - | - | $1,040 | 232 | - | - | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$1,040 232 MMBtu |
- - $ |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $570 Cost: $370 |
$310 | 20,809 | $620 | 58 | - | - | $(-360) | - | - | - | - | - | - | - |
$310 20,809 kWh |
$620 58 kW-months/year |
- - MMBtu |
$(-360) - $ |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $410 Cost: $1,020 |
$140 | 9,379 | $270 | 26 | - | - | - | - | - | - | - | - | - | - |
$140 9,379 kWh |
$270 26 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $130 Cost: - |
$80 | 5,569 | $210 | 19 | - | - | - | - | - | - | $(-160) | - | - | - |
$80 5,569 kWh |
$210 19 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
$(-160) - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 4.431 TRAIN OPERATORS FOR MAXIMUM OPERATING EFFICIENCY |
Savings: $35,000 Cost: $1,600 |
- | - | - | - | - | - | - | - | - | - | - | - | $35,000 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
- - $ |
$35,000 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $44,390 Cost: $16,740 |
$530 | 35,757 | $4,540 | 427 | $5,320 | 1,186 | $(-360) | - | $(-480) | - | $(-160) | - | $35,000 | - | $530 35,757 kWh |
$4,540 427 kW-months/year |
$5,320 1,186 MMBtu |
$(-360) - $ |
$(-480) - $ |
$(-160) - $ |
$35,000 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $41,300 Cost: $16,540 |
$450 | 30,188 | $890 | 84 | $5,320 | 1,186 | $(-360) | - | - | - | - | - | $35,000 | - | $450 30,188 kWh |
$890 84 kW-months/year |
$5,320 1,186 MMBtu |
$(-360) - $ |
- - $ |
- - $ |
$35,000 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Administrative Changes | Ancillary Material Cost | Primary Product | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Administrative Changes | Ancillary Material Cost | Primary Product |