Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Colorado State University |
---|---|
Assessment Year | 2001 |
Principal Product | Natural gas compressors and wheelchair lifts |
NAICS | n/a |
SIC | 3563 - Air And Gas Compressors |
Sales | $10,000,000-$50,000,000 |
# of Employees | 60 |
Plant Area (Sq.Ft.) | 56,600 |
Annual Production | 35 Pieces |
Production Hrs. Annual | 2,496 |
Location (State) | CO |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $13,321 | 798,400 | kWh | $0.02 |
Electricity Demand | $38,803 | 2,868 | kW-months/year | $13.53 |
Electricity Fees | $196 | - | $ | - |
Natural Gas | $51,920 | 7,072 | MMBtu | $7.34 |
TOTAL ENERGY COSTS | $104,240 | |||
RECOMMENDED SAVINGS* | $81,190 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $75,200 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Ancillary Material Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.3191 USE DEMAND CONTROLLER OR LOAD SHEDDER |
Savings: $3,880 Cost: $7,000 |
- | - | $3,880 | 288 | - | - | - | - | - | - |
- - kWh |
$3,880 288 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7221 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA |
Savings: $2,910 Cost: $5,800 |
- | - | - | - | $2,910 | 510 | - | - | - | - |
- - kWh |
- - kW-months/year |
$2,910 510 MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7447 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS |
Savings: $2,110 Cost: $7,530 |
- | - | - | - | $2,110 | 369 | - | - | - | - |
- - kWh |
- - kW-months/year |
$2,110 369 MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $410 Cost: - |
$1,040 | 62,100 | $3,770 | 280 | - | - | $(-1,370) | - | $(-3,030) | - |
$1,040 62,100 kWh |
$3,770 280 kW-months/year |
- - MMBtu |
$(-1,370) - $ |
$(-3,030) - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $380 Cost: $210 |
$280 | 16,600 | $700 | 52 | - | - | $(-600) | - | - | - |
$280 16,600 kWh |
$700 52 kW-months/year |
- - MMBtu |
$(-600) - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 4.513 RE-ARRANGE EQUIPMENT LAYOUT TO REDUCE LABOR COSTS |
Savings: $71,500 Cost: $3,200 |
- | - | - | - | - | - | $71,500 | - | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$71,500 - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $81,190 Cost: $23,740 |
$1,320 | 78,700 | $8,350 | 620 | $5,020 | 879 | $69,530 | - | $(-3,030) | - | $1,320 78,700 kWh |
$8,350 620 kW-months/year |
$5,020 879 MMBtu |
$69,530 - $ |
$(-3,030) - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $75,200 Cost: $9,210 |
$1,320 | 78,700 | $4,470 | 332 | $2,910 | 510 | $69,530 | - | $(-3,030) | - | $1,320 78,700 kWh |
$4,470 332 kW-months/year |
$2,910 510 MMBtu |
$69,530 - $ |
$(-3,030) - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Ancillary Material Cost |