Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Colorado State University |
---|---|
Assessment Year | 2002 |
Principal Product | aerospace hardware |
NAICS | n/a |
SIC | 3728 - Aircraft Parts And Equipment, Nec |
Sales | $10,000,000-$50,000,000 |
# of Employees | 250 |
Plant Area (Sq.Ft.) | 162,000 |
Annual Production | 304,000 Pieces |
Production Hrs. Annual | 8,760 |
Location (State) | CO |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $254,357 | 16,700,444 | kWh | $0.02 |
Electricity Demand | $382,855 | 58,158 | kW-months/year | $6.58 |
Electricity Fees | $1,509 | - | $ | - |
Natural Gas | $233,887 | 39,190 | MMBtu | $5.97 |
TOTAL ENERGY COSTS | $929,890 | |||
RECOMMENDED SAVINGS* | $192,030 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | - |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Other Liquid (haz) | Solid Waste (non-haz) | Personnel Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Other Liquid (haz) | Solid Waste (non-haz) | Personnel Changes | Ancillary Material Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | gal | $ | lb | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.3131 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS |
Savings: $18,890 Cost: $12,000 |
- | - | $18,890 | 2,940 | - | - | - | - | - | - | - | - |
- - kWh |
$18,890 2,940 kW-months/year |
- - gal |
- - lb |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.2511 INSULATE BARE EQUIPMENT |
Savings: $11,610 Cost: $1,980 |
$5,490 | 347,700 | $6,120 | 899 | - | - | - | - | - | - | - | - |
$5,490 347,700 kWh |
$6,120 899 kW-months/year |
- - gal |
- - lb |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE |
Savings: $9,180 Cost: $10,000 |
$5,540 | 351,700 | $3,640 | 482 | - | - | - | - | - | - | - | - |
$5,540 351,700 kWh |
$3,640 482 kW-months/year |
- - gal |
- - lb |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE |
Savings: $5,020 Cost: $2,000 |
$2,370 | 150,400 | $2,650 | 414 | - | - | - | - | - | - | - | - |
$2,370 150,400 kWh |
$2,650 414 kW-months/year |
- - gal |
- - lb |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE |
Savings: $3,440 Cost: $2,000 |
$3,440 | 218,100 | - | - | - | - | - | - | - | - | - | - |
$3,440 218,100 kWh |
- - kW-months/year |
- - gal |
- - lb |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.6241 REDUCE TEMPERATURE OF PROCESS EQUIPMENT WHEN ON STANDBY |
Savings: $2,900 Cost: - |
$1,230 | 77,900 | $1,670 | 225 | - | - | - | - | - | - | - | - |
$1,230 77,900 kWh |
$1,670 225 kW-months/year |
- - gal |
- - lb |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE |
Savings: $620 Cost: $500 |
$310 | 19,800 | $310 | 41 | - | - | - | - | - | - | - | - |
$310 19,800 kWh |
$310 41 kW-months/year |
- - gal |
- - lb |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 3.3128 UTILIZE OTHER METHODS TO REMOVE CONTAMINANTS |
Savings: $137,140 Cost: $300,000 |
- | - | - | - | - | - | $15,000 | 21,500 | $112,320 | - | $9,820 | - |
- - kWh |
- - kW-months/year |
- - gal |
$15,000 21,500 lb |
$112,320 - $ |
$9,820 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 3.5248 SEPARATE AND RECYCLE SCRAP METAL TO FOUNDRY OR FOR SALE |
Savings: $3,230 Cost: $6,500 |
- | - | - | - | $3,230 | - | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$3,230 - gal |
- - lb |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $192,030 Cost: $334,980 |
$18,380 | 1,165,600 | $33,280 | 5,001 | $3,230 | - | $15,000 | 21,500 | $112,320 | - | $9,820 | - | $18,380 1,165,600 kWh |
$33,280 5,001 kW-months/year |
$3,230 - gal |
$15,000 21,500 lb |
$112,320 - $ |
$9,820 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: - Cost: - |
- | - | - | - | - | - | - | - | - | - | - | - | - - kWh |
- - kW-months/year |
- - gal |
- - lb |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | gal | $ | lb | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||