Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Colorado State University
Assessment Year 2002
Principal Product Semiconductor materials
NAICS n/a
SIC 3674 - Semiconductors And Related Devices
Sales $10,000,000-$50,000,000
# of Employees 50
Plant Area (Sq.Ft.) 27,000
Annual Production 250,000 Pieces
Production Hrs. Annual 8,760
Location (State) CO
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $199,247 5,208,600 kWh $0.04
Electricity Demand $87,448 19,085 kW-months/year $4.58
Electricity Fees $8,808 - $ -
Natural Gas $25,096 4,204 MMBtu $5.97
TOTAL ENERGY COSTS $328,679
RECOMMENDED SAVINGS* $36,120 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $2,420
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Personnel Changes Administrative Changes Electricity Usage Electricity Demand Personnel Changes Administrative Changes
$ kWh $ kW-months/year $ $ $ $
01: 2.7252 UTILIZE AN EVAPORATIVE AIR PRE-COOLER OR OTHER HEAT EXCHANGER IN AC SYSTEM Savings:
$12,040
Cost:
$9,500
$8,560 294,200 $3,480 479 - - - - $8,560
294,200
kWh
$3,480
479
kW-months/year
-
-
$
-
-
$
02: 2.3212 OPTIMIZE PLANT POWER FACTOR Savings:
$10,160
Cost:
$14,010
- - $10,160 1,394 - - - - -
-
kWh
$10,160
1,394
kW-months/year
-
-
$
-
-
$
03: 2.2511 INSULATE BARE EQUIPMENT Savings:
$4,380
Cost:
$990
$4,380 150,600 - - - - - - $4,380
150,600
kWh
-
-
kW-months/year
-
-
$
-
-
$
04: 2.7234 USE HEAT PUMP FOR SPACE CONDITIONING Savings:
$4,020
Cost:
-
$2,990 102,700 $1,030 141 - - - - $2,990
102,700
kWh
$1,030
141
kW-months/year
-
-
$
-
-
$
05: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$2,420
Cost:
$190
$2,070 71,200 $710 98 $(-360) - - - $2,070
71,200
kWh
$710
98
kW-months/year
$(-360)
-
$
-
-
$
06: 2.3191 USE DEMAND CONTROLLER OR LOAD SHEDDER Savings:
$2,290
Cost:
$1,200
- - $3,490 480 - - $(-1,200) - -
-
kWh
$3,490
480
kW-months/year
-
-
$
$(-1,200)
-
$
07: 2.7111 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS Savings:
$370
Cost:
$300
$280 9,500 $90 13 - - - - $280
9,500
kWh
$90
13
kW-months/year
-
-
$
-
-
$
08: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$340
Cost:
-
$1,070 36,000 $480 67 $20 - $(-1,230) - $1,070
36,000
kWh
$480
67
kW-months/year
$20
-
$
$(-1,230)
-
$
09: 2.7221 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA Savings:
$100
Cost:
-
$100 3,600 - - - - - - $100
3,600
kWh
-
-
kW-months/year
-
-
$
-
-
$
TOTAL RECOMMENDED Savings:
$36,120
Cost:
$26,190
$19,450 667,800 $19,440 2,672 $(-340) - $(-2,430) - $19,450
667,800
kWh
$19,440
2,672
kW-months/year
$(-340)
-
$
$(-2,430)
-
$
TOTAL IMPLEMENTED Savings:
$2,420
Cost:
$190
$2,070 71,200 $710 98 $(-360) - - - $2,070
71,200
kWh
$710
98
kW-months/year
$(-360)
-
$
-
-
$
Savings
Cost
$ kWh $ kW-months/year $ $ $ $
Electricity Usage Electricity Demand Personnel Changes Administrative Changes Electricity Usage Electricity Demand Personnel Changes Administrative Changes