Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Colorado State University |
---|---|
Assessment Year | 2003 |
Principal Product | Biopharmaceuticals |
NAICS | 323111 - Commercial Printing (except Screen and Books) |
SIC | 2836 - Biological Products Exc. Diagnostic |
Sales | >$500,000,000 |
# of Employees | 150 |
Plant Area (Sq.Ft.) | 135,000 |
Annual Production | 2,205 Pounds |
Production Hrs. Annual | 8,760 |
Location (State) | CO |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $189,373 | 10,354,308 | kWh | $0.02 |
Electricity Demand | $243,083 | 17,660 | kW-months/year | $13.76 |
Electricity Fees | $204 | - | $ | - |
Natural Gas | $389,578 | 73,573 | MMBtu | $5.30 |
TOTAL ENERGY COSTS | $906,336 | |||
RECOMMENDED SAVINGS* | $25,174 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $1,460 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Personnel Changes | Electricity Usage | Electricity Demand | Personnel Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.3137 USE POWER DURING OFF-PEAK PERIODS |
Savings: $12,470 Cost: $10,000 |
- | - | $12,470 | 900 | - | - |
- - kWh |
$12,470 900 kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.2628 UTILIZE A LESS EXPENSIVE COOLING METHOD |
Savings: $10,530 Cost: $39,900 |
$6,230 | 227,300 | $4,300 | 310 | - | - |
$6,230 227,300 kWh |
$4,300 310 kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $304 Cost: $508 |
$180 | 6,584 | $124 | 9 | - | - |
$180 6,584 kWh |
$124 9 kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $1,460 Cost: $260 |
$1,150 | 41,800 | $790 | 57 | $(-480) | - |
$1,150 41,800 kWh |
$790 57 kW-months/year |
$(-480) - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7111 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS |
Savings: $410 Cost: $260 |
$240 | 10,400 | $170 | 12 | - | - |
$240 10,400 kWh |
$170 12 kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $25,174 Cost: $50,928 |
$7,800 | 286,084 | $17,854 | 1,288 | $(-480) | - | $7,800 286,084 kWh |
$17,854 1,288 kW-months/year |
$(-480) - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $1,460 Cost: $260 |
$1,150 | 41,800 | $790 | 57 | $(-480) | - | $1,150 41,800 kWh |
$790 57 kW-months/year |
$(-480) - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||