Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Colorado State University |
---|---|
Assessment Year | 2003 |
Principal Product | Lumber |
NAICS | 321912 - Cut Stock, Resawing Lumber, and Planing |
SIC | 2421 - Sawmills And Planing Mills, General |
Sales | $10,000,000-$50,000,000 |
# of Employees | 100 |
Plant Area (Sq.Ft.) | 116,800 |
Annual Production | 36,957,000 Thousand Feet |
Production Hrs. Annual | 6,006 |
Location (State) | WY |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $372,646 | 12,088,221 | kWh | $0.03 |
Electricity Demand | $172,764 | 28,432 | kW-months/year | $6.08 |
Electricity Fees | $(-156) | - | $ | - |
LPG | $5,504 | 623 | MMBtu | $8.83 |
TOTAL ENERGY COSTS | $550,758 | |||
RECOMMENDED SAVINGS* | $24,611 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $16,127 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Personnel Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Personnel Changes | Ancillary Material Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $10,560 Cost: $770 |
$7,780 | 420,200 | $3,500 | 575 | $(-720) | - | - | - |
$7,780 420,200 kWh |
$3,500 575 kW-months/year |
$(-720) - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $4,400 Cost: $11,160 |
$2,100 | 113,100 | $1,500 | 246 | - | - | $800 | - |
$2,100 113,100 kWh |
$1,500 246 kW-months/year |
- - $ |
$800 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $821 Cost: $3,286 |
$467 | 25,190 | $354 | 58 | - | - | - | - |
$467 25,190 kWh |
$354 58 kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $3,360 Cost: $8,160 |
$1,810 | 97,700 | $1,550 | 254 | - | - | - | - |
$1,810 97,700 kWh |
$1,550 254 kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7134 USE PHOTOCELL CONTROLS |
Savings: $2,090 Cost: $1,080 |
$970 | 52,700 | $800 | 130 | - | - | $320 | - |
$970 52,700 kWh |
$800 130 kW-months/year |
- - $ |
$320 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $1,602 Cost: $5,894 |
$1,044 | 56,520 | $680 | 111 | - | - | $(-122) | - |
$1,044 56,520 kWh |
$680 111 kW-months/year |
- - $ |
$(-122) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7132 INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS |
Savings: $660 Cost: $210 |
$320 | 17,500 | $260 | 43 | - | - | $80 | - |
$320 17,500 kWh |
$260 43 kW-months/year |
- - $ |
$80 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $394 Cost: $1,644 |
$350 | 19,006 | $216 | 36 | - | - | $(-172) | - |
$350 19,006 kWh |
$216 36 kW-months/year |
- - $ |
$(-172) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $164 Cost: $546 |
$142 | 2,932 | - | - | - | - | $22 | - |
$142 2,932 kWh |
- - kW-months/year |
- - $ |
$22 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 2.7122 DISCONNECT BALLASTS |
Savings: $560 Cost: $330 |
$190 | 10,500 | $330 | 54 | - | - | $40 | - |
$190 10,500 kWh |
$330 54 kW-months/year |
- - $ |
$40 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $24,611 Cost: $33,080 |
$15,173 | 815,348 | $9,190 | 1,507 | $(-720) | - | $968 | - | $15,173 815,348 kWh |
$9,190 1,507 kW-months/year |
$(-720) - $ |
$968 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $16,127 Cost: $12,884 |
$10,931 | 591,116 | $5,810 | 953 | $(-720) | - | $106 | - | $10,931 591,116 kWh |
$5,810 953 kW-months/year |
$(-720) - $ |
$106 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Personnel Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Personnel Changes | Ancillary Material Cost |