Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Colorado State University
Assessment Year 2003
Principal Product Photovoltaic & fiber optic equipment
NAICS 334413 - Semiconductor and Related Device Manufacturing
SIC 3674 - Semiconductors And Related Devices
Sales $50,000,000-$100,000,000
# of Employees 250
Plant Area (Sq.Ft.) 135,750
Annual Production 2,100,000 Pieces
Production Hrs. Annual 8,760
Location (State) NM
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $736,104 18,515,100 kWh $0.04
Electricity Demand $196,329 28,953 kW-months/year $6.78
Electricity Fees $140,671 - $ -
Natural Gas $335,029 57,028 MMBtu $5.87
TOTAL ENERGY COSTS $1,408,133
RECOMMENDED SAVINGS* $59,790 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $20,940
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Electricity Usage Electricity Demand
$ kWh $ kW-months/year
01: 2.4226 USE / PURCHASE OPTIMUM SIZED COMPRESSOR Savings:
$20,940
Cost:
$4,360
$14,940 378,000 $6,000 518 $14,940
378,000
kWh
$6,000
518
kW-months/year
02: 2.7252 UTILIZE AN EVAPORATIVE AIR PRE-COOLER OR OTHER HEAT EXCHANGER IN AC SYSTEM Savings:
$13,340
Cost:
$14,640
$9,830 258,000 $3,510 303 $9,830
258,000
kWh
$3,510
303
kW-months/year
03: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM Savings:
$8,850
Cost:
$16,010
$8,850 226,500 - - $8,850
226,500
kWh
-
-
kW-months/year
04: 2.3191 USE DEMAND CONTROLLER OR LOAD SHEDDER Savings:
$6,000
Cost:
$3,000
- - $6,000 518 -
-
kWh
$6,000
518
kW-months/year
05: 2.4323 USE OPTIMUM SIZE AND CAPACITY EQUIPMENT Savings:
$5,720
Cost:
$13,150
$4,080 103,400 $1,640 142 $4,080
103,400
kWh
$1,640
142
kW-months/year
06: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS Savings:
$4,940
Cost:
$10,310
$3,500 88,500 $1,440 125 $3,500
88,500
kWh
$1,440
125
kW-months/year
TOTAL RECOMMENDED Savings:
$59,790
Cost:
$61,470
$41,200 1,054,400 $18,590 1,606 $41,200
1,054,400
kWh
$18,590
1,606
kW-months/year
TOTAL IMPLEMENTED Savings:
$20,940
Cost:
$4,360
$14,940 378,000 $6,000 518 $14,940
378,000
kWh
$6,000
518
kW-months/year
Savings
Cost
$ kWh $ kW-months/year
Electricity Usage Electricity Demand Electricity Usage Electricity Demand