Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Colorado State University |
---|---|
Assessment Year | 2003 |
Principal Product | soft drinks |
NAICS | 312111 - Soft Drink Manufacturing |
SIC | 2086 - Bottled And Canned Soft Drinks |
Sales | $100,000,000-$500,000,000 |
# of Employees | 650 |
Plant Area (Sq.Ft.) | 616,684 |
Annual Production | 30,000,000 Pieces |
Production Hrs. Annual | 8,760 |
Location (State) | CO |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $304,911 | 14,011,271 | kWh | $0.02 |
Electricity Demand | $417,155 | 31,370 | kW-months/year | $13.30 |
Electricity Fees | $384 | - | $ | - |
Natural Gas | $285,537 | 47,780 | MMBtu | $5.98 |
TOTAL ENERGY COSTS | $1,281,647 | |||
RECOMMENDED SAVINGS* | $166,899 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $46,114 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Personnel Changes | Ancillary Material Cost | Water Consumption | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Personnel Changes | Ancillary Material Cost | Water Consumption | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | Tgal | $ | $ | $ | $ | $ | Tgal | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $63,500 Cost: $148,580 |
$48,240 | 1,503,400 | $28,060 | 2,102 | - | - | - | - | - | - | $(-12,800) | - | - | - |
$48,240 1,503,400 kWh |
$28,060 2,102 kW-months/year |
- - MMBtu |
- - Tgal |
- - $ |
$(-12,800) - $ |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $17,410 Cost: $63,410 |
$9,770 | 304,200 | $5,610 | 420 | - | - | - | - | $980 | - | $1,050 | - | - | - |
$9,770 304,200 kWh |
$5,610 420 kW-months/year |
- - MMBtu |
- - Tgal |
$980 - $ |
$1,050 - $ |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $16,760 Cost: $310 |
$10,680 | 332,600 | $6,080 | 455 | - | - | - | - | - | - | - | - | - | - |
$10,680 332,600 kWh |
$6,080 455 kW-months/year |
- - MMBtu |
- - Tgal |
- - $ |
- - $ |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.1222 INSTALL TURBULATORS |
Savings: $12,720 Cost: $8,820 |
- | - | - | - | $8,980 | 1,658 | - | - | $240 | - | $3,500 | - | - | - |
- - kWh |
- - kW-months/year |
$8,980 1,658 MMBtu |
- - Tgal |
$240 - $ |
$3,500 - $ |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $14,454 Cost: $4,810 |
$11,097 | 345,819 | $6,449 | 483 | - | - | - | - | - | - | $(-3,092) | - | - | - |
$11,097 345,819 kWh |
$6,449 483 kW-months/year |
- - MMBtu |
- - Tgal |
- - $ |
$(-3,092) - $ |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $1,495 Cost: $2,618 |
$939 | 29,265 | $556 | 42 | - | - | - | - | - | - | - | - | - | - |
$939 29,265 kWh |
$556 42 kW-months/year |
- - MMBtu |
- - Tgal |
- - $ |
- - $ |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $2,670 Cost: $4,320 |
$660 | 20,600 | $370 | 28 | - | - | - | - | $850 | - | $790 | - | - | - |
$660 20,600 kWh |
$370 28 kW-months/year |
- - MMBtu |
- - Tgal |
$850 - $ |
$790 - $ |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.2135 REPAIR AND ELIMINATE STEAM LEAKS |
Savings: $1,280 Cost: $220 |
- | - | - | - | $1,280 | 236 | - | - | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$1,280 236 MMBtu |
- - Tgal |
- - $ |
- - $ |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.7141 LOWER LIGHT FIXTURES IN HIGH CEILING AREAS |
Savings: $980 Cost: $1,200 |
$620 | 19,400 | $360 | 27 | - | - | - | - | - | - | - | - | - | - |
$620 19,400 kWh |
$360 27 kW-months/year |
- - MMBtu |
- - Tgal |
- - $ |
- - $ |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $460 Cost: $390 |
$230 | 7,200 | $200 | 15 | - | - | - | - | $20 | - | $10 | - | - | - |
$230 7,200 kWh |
$200 15 kW-months/year |
- - MMBtu |
- - Tgal |
$20 - $ |
$10 - $ |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
11: 3.4113 TREAT AND REUSE RINSE WATERS |
Savings: $31,660 Cost: $19,160 |
$(-410) | (-12,800) | $(-270) | (-20) | - | - | $26,130 | 4,153,000 | - | - | - | - | $6,210 | - |
$(-410) (-12,800) kWh |
$(-270) (-20) kW-months/year |
- - MMBtu |
$26,130 4,153,000 Tgal |
- - $ |
- - $ |
$6,210 - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
12: 3.5317 SELL / OFFER BY-PRODUCT AS ANIMAL FEED |
Savings: $3,510 Cost: $11,830 |
$(-70) | (-2,100) | $(-130) | (-10) | - | - | $3,710 | - | - | - | - | - | - | - |
$(-70) (-2,100) kWh |
$(-130) (-10) kW-months/year |
- - MMBtu |
$3,710 - Tgal |
- - $ |
- - $ |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $166,899 Cost: $265,668 |
$81,756 | 2,547,584 | $47,285 | 3,542 | $10,260 | 1,894 | $29,840 | 4,153,000 | $2,090 | - | $(-10,542) | - | $6,210 | - | $81,756 2,547,584 kWh |
$47,285 3,542 kW-months/year |
$10,260 1,894 MMBtu |
$29,840 4,153,000 Tgal |
$2,090 - $ |
$(-10,542) - $ |
$6,210 - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $46,114 Cost: $23,970 |
$10,687 | 333,019 | $6,179 | 463 | - | - | $26,130 | 4,153,000 | - | - | $(-3,092) | - | $6,210 | - | $10,687 333,019 kWh |
$6,179 463 kW-months/year |
- - MMBtu |
$26,130 4,153,000 Tgal |
- - $ |
$(-3,092) - $ |
$6,210 - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | Tgal | $ | $ | $ | $ | $ | Tgal | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Personnel Changes | Ancillary Material Cost | Water Consumption | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Personnel Changes | Ancillary Material Cost | Water Consumption |