Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Colorado State University |
---|---|
Assessment Year | 2006 |
Principal Product | Paper cups and plates |
NAICS | 322219 - Other Paperboard Container Manufacturing |
SIC | 2656 - Sanitary Food Containers |
Sales | $10,000,000-$50,000,000 |
# of Employees | 250 |
Plant Area (Sq.Ft.) | 170,000 |
Annual Production | 1,300,000,000 Pieces |
Production Hrs. Annual | 6,361 |
Location (State) | NM |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $405,688 | 10,713,600 | kWh | $0.04 |
Electricity Demand | $168,168 | 21,696 | kW-months/year | $7.75 |
Electricity Fees | $64,749 | - | $ | - |
Natural Gas | $193,394 | 18,148 | MMBtu | $10.66 |
TOTAL ENERGY COSTS | $831,999 | |||
RECOMMENDED SAVINGS* | $48,120 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $5,220 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Administrative Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Administrative Changes | Ancillary Material Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.1121 USE INSULATION IN FURNACES TO FACILITATE HEATING / COOLING |
Savings: $4,450 Cost: $770 |
- | - | - | - | $4,450 | 451 | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$4,450 451 MMBtu |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.2136 INSTALL / REPAIR INSULATION ON STEAM LINES |
Savings: $2,900 Cost: $1,320 |
- | - | - | - | $2,900 | 294 | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$2,900 294 MMBtu |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $2,660 Cost: $100 |
$1,670 | 42,000 | $990 | 93 | - | - | - | - | - | - | - | - |
$1,670 42,000 kWh |
$990 93 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $560 Cost: $658 |
$360 | 9,361 | $200 | 19 | - | - | - | - | - | - | - | - |
$360 9,361 kWh |
$200 19 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE |
Savings: $1,880 Cost: - |
$1,230 | 32,200 | $650 | 61 | - | - | - | - | - | - | - | - |
$1,230 32,200 kWh |
$650 61 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $670 Cost: $1,390 |
$440 | 11,600 | $230 | 22 | - | - | - | - | - | - | - | - |
$440 11,600 kWh |
$230 22 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.1134 ELIMINATE LEAKS IN COMBUSTIBLE GAS LINES |
Savings: $560 Cost: $500 |
- | - | - | - | $560 | 57 | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$560 57 MMBtu |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $28,940 Cost: $70,090 |
$18,930 | 493,600 | $8,890 | 836 | - | - | $280 | - | - | - | $840 | - |
$18,930 493,600 kWh |
$8,890 836 kW-months/year |
- - MMBtu |
$280 - $ |
- - $ |
$840 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY |
Savings: $3,850 Cost: $32,600 |
$1,060 | 23,000 | $850 | 80 | - | - | - | - | $1,940 | - | - | - |
$1,060 23,000 kWh |
$850 80 kW-months/year |
- - MMBtu |
- - $ |
$1,940 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $1,280 Cost: $680 |
$680 | 16,300 | $530 | 50 | - | - | $20 | - | - | - | $50 | - |
$680 16,300 kWh |
$530 50 kW-months/year |
- - MMBtu |
$20 - $ |
- - $ |
$50 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
11: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $210 Cost: $780 |
$180 | 5,000 | $30 | 3 | - | - | - | - | - | - | - | - |
$180 5,000 kWh |
$30 3 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
12: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $160 Cost: $500 |
$40 | 1,000 | $10 | 1 | - | - | $50 | - | - | - | $60 | - |
$40 1,000 kWh |
$10 1 kW-months/year |
- - MMBtu |
$50 - $ |
- - $ |
$60 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $48,120 Cost: $109,388 |
$24,590 | 634,061 | $12,380 | 1,165 | $7,910 | 802 | $350 | - | $1,940 | - | $950 | - | $24,590 634,061 kWh |
$12,380 1,165 kW-months/year |
$7,910 802 MMBtu |
$350 - $ |
$1,940 - $ |
$950 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $5,220 Cost: $2,438 |
$2,750 | 68,661 | $1,730 | 163 | $560 | 57 | $70 | - | - | - | $110 | - | $2,750 68,661 kWh |
$1,730 163 kW-months/year |
$560 57 MMBtu |
$70 - $ |
- - $ |
$110 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Administrative Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Administrative Changes | Ancillary Material Cost |