Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Colorado State University |
---|---|
Assessment Year | 2007 |
Principal Product | Aluminum beverage containers |
NAICS | 332431 - Metal Can Manufacturing |
SIC | 3411 - Metal Cans |
Sales | $100,000,000-$500,000,000 |
# of Employees | 350 |
Plant Area (Sq.Ft.) | 330,000 |
Annual Production | 2,147,483,647 Pieces |
Production Hrs. Annual | 8,760 |
Location (State) | CO |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $1,695,916 | 47,784,906 | kWh | $0.04 |
Electricity Demand | $894,041 | 69,935 | kW-months/year | $12.78 |
Electricity Fees | $1,566 | - | $ | - |
Natural Gas | $1,322,170 | 147,235 | MMBtu | $8.98 |
TOTAL ENERGY COSTS | $3,913,693 | |||
RECOMMENDED SAVINGS* | $141,720 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | - |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Administrative Changes | Electricity Usage | Electricity Demand | Natural Gas | Administrative Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.1113 REDUCE COMBUSTION AIR FLOW TO OPTIMUM |
Savings: $77,320 Cost: $140,620 |
$4,720 | 146,100 | $2,720 | 201 | $69,880 | 8,902 | - | - |
$4,720 146,100 kWh |
$2,720 201 kW-months/year |
$69,880 8,902 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.1116 IMPROVE COMBUSTION CONTROL CAPABILITY |
Savings: $37,380 Cost: $112,000 |
- | - | - | - | $37,380 | 4,762 | - | - |
- - kWh |
- - kW-months/year |
$37,380 4,762 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.3415 USE A FOSSIL FUEL ENGINE TO COGENERATE ELECTRICITY OR MOTIVE POWER; AND UTILIZE HEAT |
Savings: $15,090 Cost: $338,400 |
$46,010 | 1,423,100 | $27,800 | 2,052 | $(-32,320) | (-4,117) | $(-26,400) | - |
$46,010 1,423,100 kWh |
$27,800 2,052 kW-months/year |
$(-32,320) (-4,117) MMBtu |
$(-26,400) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4131 SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY |
Savings: $8,960 Cost: $14,520 |
$5,690 | 176,100 | $3,270 | 241 | - | - | - | - |
$5,690 176,100 kWh |
$3,270 241 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.1213 DIRECT WARMEST AIR TO COMBUSTION INTAKE |
Savings: $1,660 Cost: $4,250 |
- | - | - | - | $1,660 | 211 | - | - |
- - kWh |
- - kW-months/year |
$1,660 211 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY |
Savings: $1,310 Cost: $11,000 |
$470 | 14,600 | $840 | 62 | - | - | - | - |
$470 14,600 kWh |
$840 62 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $141,720 Cost: $620,790 |
$56,890 | 1,759,900 | $34,630 | 2,556 | $76,600 | 9,758 | $(-26,400) | - | $56,890 1,759,900 kWh |
$34,630 2,556 kW-months/year |
$76,600 9,758 MMBtu |
$(-26,400) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: - Cost: - |
- | - | - | - | - | - | - | - | - - kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||